background image

Installation Guide

S S 

Digital  witching  ystems Australia

S

S

 A 

D

Operation Overview

Mount the Combo 64 in a dry safe, secure place away from the heat and humidity. 
If possible,select an inconspicuous area that will not be routinely accessed. 
Make sure the device is kept clear of moving parts or debris.
Also ensure the device is safe from moisture or liquids.

Please ensure you read this complete manual as fitting instructions and testing 
procedures areincorporated throughout. 

  

General Input 1 and General Input 2 are momentary inputs, briefly connect the input to 

b or battery negative (depending on the DIP switch setting) to toggle on and off 

General Output 1 and General Output 2 respectively.   

 

If General Input DIP switch is enabled (ON), releasing the Park Brake will switch OFF 

General Output 1 and General Output 2.   

 

The Door Switch and Park Brake switches are set to Low Active (by Default) but can be 

configured either way. If Door Switch is active (Open) while Park Brake is NOT active 

(OFF), the on board buzzer will immediately sound for 5s before alarm (Output 4) is 

activated. Applying the Park Brake will disable BOTH buzzer and alarm immediately. 

Once the door is opened, the alarms latch on unless the park Brake is applied. It is good 

practice to apply the park brake BEFORE opening the door.   

If Daytime Running Light is set to be controlled by Battery Voltage sensing, Day Time 

Running Light (Output 3) is turned ON with a delay of 5s once the engine is running and 

the Alternator is charging. If either the Head Light or Park Light is turned ON the DRL’s 

are turned OFF immediately. The DRL’s are also turned off with a delay of 20s once the 

battery voltage falls below the pre set threshold setting.   

 

If Daytime Running Light is set to be controlled by Ignition Switch, Daytime Running 

Light (Output 3) is turned ON with a delay of 5s once the Ignition Switch is turned ON. If 

Head Light is turned ON the DRL are turned OFF immediately. The DRL is turned OFF with 

a delay of 20s once the Ignition Switch is turned OFF

Note: Disconnect Battery before doing any connection.

Summary of Contents for Combo 64

Page 1: ...n a driver that the hand brake is not on can turn on DRL s as a preset function turn beacons on and has many more applications Part No DSS CBO64 The Combo 64 is an advanced safety device aimed to simplify control and warn a driver in case of a problem It utilises the latest digital micro controller technology to ensure reliability and performance It allows for automatic control of preset devices i...

Page 2: ...Battery Battery Fuse Fuse Fuse Horn D R L D R L Beacon Accessory Battery Battery Battery Output 4 Common Output 4 NC Output 4 NO Output 3 Output 3 Output 2 Output 2 Output 1 Output 1 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Typical Connection Battery 1 Ensure the polarity of device connected to input output 2 Inputs can be positive or negative switches Configuration is done via DIP switch s...

Page 3: ...or Switch is active Open while Park Brake is NOT active OFF the on board buzzer will immediately sound for 5s before alarm Output 4 is activated Applying the Park Brake will disable BOTH buzzer and alarm immediately Once the door is opened the alarms latch on unless the park Brake is applied It is good practice to apply the park brake BEFORE opening the door If Daytime Running Light is set to be c...

Page 4: ...2 Output 2 Output 1 Output 1 Name Description Maximum Fuse Battery Connect to battery Battery Connect to battery Battery Connect to battery Output 4 Common Connect to EITHER Battery OR Battery for Output 4 5A Output 4 NC Mobile Phone optional 5A Output 4 NO External Alarm 5A Output 3 Day Time Running Light 10A Output 2 General Output 2 10A Output 1 General Output 1 10A Depends on Daytime Running L...

Page 5: ...tion Switch is ON Turn off 20s delay when Ignition Switch is OFF General Input Selection When the Park Brake is Released Switch Off General Output 1 2 Disabled Enabled General Input 1 Selection Select General Input 1 to be Momentary STB or STG STG Negative Switching STB Positive Switching General Input 2 Selection Select General Input 2 to be Momentary STB or STG STG Negative Switching STB Positiv...

Page 6: ...Output 3 Output 2 Output 2 Output 1 Output 1 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Typical Park Brake Connection Battery 1 Ensure the polarity of device connected to input output 2 Inputs can be positive or negative switches Configuration is done via DIP switch settings Please refer to installation manual Hand Brake Door Switch 1 Disconnect Battery before doing any connection 2 Connect P...

Page 7: ...ce to be operated by General Input 1 and General Input 2 to Safe Guard 64 General Output 1 and General Output 2 respectively 4 Ensure the polarity of Momentary Switch be Switch to Battery STB 5 Connect the Battery to Safe Guard 64 6 Press Momentary Switch 1 once the device connect to General Output 1 will switch ON OFF status Press the button again to ensure that it will switch ON OFF again 7 Pres...

Page 8: ...nect Ignition Switch to the Combo 64 Ignition Switch input respectively 3 Connect Daytime Running Light to Combo 64 Daytime Running Light Output 4 Ensure the polarity Ignition Switch and set the DIP switch setting accordingly 5 Connect the Battery to Combo 64 6 Switch OFF BOTH Park Light Ignition Switch Daytime Running Light should turn OFF 7 Switch ON Ignition Switch Daytime Running Light should ...

Reviews: