background image

S S 

Digital  witching  ystems Australia

S

S

 A 

D

Dip Switch  Configuration

 

 

Voltage

Daytime Running Light Trigger Setting

General Input Selection

General Input 1 Selection

General Input 2 Selection

Door Switch Selection

Park Brake Selection

Work Light Selection

Hi Beam Selection

O

N

 

O

N

 

 

O

N

 

Switch to Left

Switch to Right

Note: Red LED lights up when the DIP switch

is switched to right.

Name 

Description 

Switch to Left 

Switch to Right 

Voltage 

+24V/+12V Selection 

12V 

24V 

Daytime 

Running 

Light Trigger 

Setting 

Select to control Daytime 

Running Light using Battery 

Voltage OR Ignition Switch 

 

Voltage Sense 

For 24V System: turn 

on (5s delay) at 27.4V/ 

turn off (20s delay) at 

26.8V 

For 12V System: turn 

on (5s delay) at 13.7V/ 

turn off (20s delay) at 

13.4V 

Ignition Sense 

Turn on (5s 

delay) when 

Ignition Switch 

is ON 

Turn off (20s 

delay) when 

Ignition Switch 

is OFF 

General Input 

Selection 

When the Park Brake is 

Released Switch Off General 

Output 1/2 

Disabled 

Enabled 

General Input 

1 Selection 

Select General Input 1 to be 

Momentary STB or STG 

STG (Negative 

Switching) 

STB (Positive 

Switching) 

General Input 

2 Selection 

Select General Input 2 to be 

Momentary STB or STG 

STG (Negative 

Switching) 

STB (Positive 

Switching) 

Door Switch 

Selection 

Select Door Switch Input to be 

STB or STG 

STG (Negative 

Switching) 

STB (Positive 

Switching) 

Park Brake 

Selection 

Select Park Brake Input to be 

STB or STG 

STG (Negative 

Switching) 

STB (Positive 

Switching) 

Park Light / 

Ignition 

Switch 

Selection* 

Select Work Light / Ignition 

Switch Input to be STB or STG 

STG (Negative 

Switching) 

STB (Positive 

Switching) 

Head Lights 

Selection 

Select Head Lights Input to be 

STB or STG 

STG (Negative 

Switching) 

STB (Positive 

Switching) 

 

* Depends on Daytime Running Light Trigger Setting, Input 5 would be operated as Park Light OR Ignition Switch

Summary of Contents for Combo 64

Page 1: ...n a driver that the hand brake is not on can turn on DRL s as a preset function turn beacons on and has many more applications Part No DSS CBO64 The Combo 64 is an advanced safety device aimed to simplify control and warn a driver in case of a problem It utilises the latest digital micro controller technology to ensure reliability and performance It allows for automatic control of preset devices i...

Page 2: ...Battery Battery Fuse Fuse Fuse Horn D R L D R L Beacon Accessory Battery Battery Battery Output 4 Common Output 4 NC Output 4 NO Output 3 Output 3 Output 2 Output 2 Output 1 Output 1 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Typical Connection Battery 1 Ensure the polarity of device connected to input output 2 Inputs can be positive or negative switches Configuration is done via DIP switch s...

Page 3: ...or Switch is active Open while Park Brake is NOT active OFF the on board buzzer will immediately sound for 5s before alarm Output 4 is activated Applying the Park Brake will disable BOTH buzzer and alarm immediately Once the door is opened the alarms latch on unless the park Brake is applied It is good practice to apply the park brake BEFORE opening the door If Daytime Running Light is set to be c...

Page 4: ...2 Output 2 Output 1 Output 1 Name Description Maximum Fuse Battery Connect to battery Battery Connect to battery Battery Connect to battery Output 4 Common Connect to EITHER Battery OR Battery for Output 4 5A Output 4 NC Mobile Phone optional 5A Output 4 NO External Alarm 5A Output 3 Day Time Running Light 10A Output 2 General Output 2 10A Output 1 General Output 1 10A Depends on Daytime Running L...

Page 5: ...tion Switch is ON Turn off 20s delay when Ignition Switch is OFF General Input Selection When the Park Brake is Released Switch Off General Output 1 2 Disabled Enabled General Input 1 Selection Select General Input 1 to be Momentary STB or STG STG Negative Switching STB Positive Switching General Input 2 Selection Select General Input 2 to be Momentary STB or STG STG Negative Switching STB Positiv...

Page 6: ...Output 3 Output 2 Output 2 Output 1 Output 1 Input 6 Input 5 Input 4 Input 3 Input 2 Input 1 Typical Park Brake Connection Battery 1 Ensure the polarity of device connected to input output 2 Inputs can be positive or negative switches Configuration is done via DIP switch settings Please refer to installation manual Hand Brake Door Switch 1 Disconnect Battery before doing any connection 2 Connect P...

Page 7: ...ce to be operated by General Input 1 and General Input 2 to Safe Guard 64 General Output 1 and General Output 2 respectively 4 Ensure the polarity of Momentary Switch be Switch to Battery STB 5 Connect the Battery to Safe Guard 64 6 Press Momentary Switch 1 once the device connect to General Output 1 will switch ON OFF status Press the button again to ensure that it will switch ON OFF again 7 Pres...

Page 8: ...nect Ignition Switch to the Combo 64 Ignition Switch input respectively 3 Connect Daytime Running Light to Combo 64 Daytime Running Light Output 4 Ensure the polarity Ignition Switch and set the DIP switch setting accordingly 5 Connect the Battery to Combo 64 6 Switch OFF BOTH Park Light Ignition Switch Daytime Running Light should turn OFF 7 Switch ON Ignition Switch Daytime Running Light should ...

Reviews: