S S
Digital witching ystems Australia
S
S
A
D
!
Head Lights
Ignition Switch / Park Lights
Car Battery
B
Fuse
Horn
D.R.L.
D.R.L.
Battery +
Battery +
Battery -
Output 4 Common
Output 4 NC
Output 4 NO
Output 3
Output 3
Output 2
Output 2
Output 1
Output 1
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
Typical DRL Connection
Battery -
1. Ensure the polarity of device connected to input
/output
2. Inputs can be positive or negative switches
.
Configuration is done via DIP switch settings
. Please
refer to installation manual .
1. Disconnect Battery before doing any connection.
2. Connect Momentary Switch 1 and 2 to the Safe Guard 64 General Input 1 and General Input 2
respectively.
3. Connect device to be operated by General Input 1 and General Input 2 to Safe Guard 64 General
Output 1 and General Output 2 respectively.
4. Ensure the polarity of Momentary Switch be Switch to Battery (STB).
5. Connect the Battery to Safe Guard 64.
6. Press Momentary Switch 1 once, the device connect to General Output 1 will switch ON/OFF status.
Press the button again to ensure that it will switch ON/OFF again.
7. Press Momentary Switch 2 once, the device connect to General Output 2 will switch ON/OFF status.
Press the button again to ensure that it will switch ON/OFF again.
8. If
“
General Input Selection” DIP switch setting is enabled, release the Park Brake, BOTH General
Output 1 and General Output 2 will switch OFF.
Supply Voltage
+12V to 24V Nominal (+28V Max)
Input Voltage
0V to +24V
Combo 64
Combo 64
Combo 64
Testing Procedure Day Time Running Lights
General Input Switch 1 & 2
Electrical Parameters