Warning 

The following basic requirements must be strictly observed, to avoid potential personal injury and 

equipment or property damages to you or any person nearby. The basic requirements include without 

limitation to the following: 

Power source/power cable 

• Please disconnect the device from power source by 

pulling the plug other than the power cord. Pulling the 

power cord may result in damages. 
• Please keep the power cord away from heat source. 

Do not overbend the power cord or place it anywhere 

it can be stepped on or may cause to trip. 
• This is connected to power source via the plug and 

any failure or danger occurs, the user can disconnect 

the device from power source by pulling out the plug 

out from the socket, therefore, it is required that the 

power socket should be located somewhere with easy 

access. 
• The device is not completely disconnected from 

power source when it is switched "OFF". For sake of 

safety, please disconnect the device from the socket if 

it is not in user. 

Positioning 

• Please disconnect the device from power source 

before relocating the device. 
• For avoiding deformation of panels and damages to 

internal components, please do NOT place the device 

where there is heavy dust or violent vibration, or 

where it is extremely cold or hot. 
• Please keep this device off water drops or splash or 

vase filled with water or any other articles of similar 

nature. 

Connection 

• Please disconnect other equipment from power 

source before they are connected to this product. 

Please tune volume to its minimum level before the 

device is powered ON or OFF. 
• All terminals on the device marked with 

  are live 

and  dangerous,  and  should  be  connected  by  trained 
personnel. 

When abnormal conditions are realized 

• Please disconnect the device from power source 

immediately in case the power cord is worn or 

damaged or if the sound is suddenly cut off or any 

abnormal odor or smoke comes out from the device, 

and then have the device inspected and repaired by 

professional personnel.

 

Precautions in Operation 

• Please do NOT insert any finger into any gap or 

opening of the device. 
• Please prevent foreign objects (paper, plastics or 

metal etc.) from being inserted or falling into any gap 

or opening of the device. In such case, please cut off 

power source immediately. 
• Please do NOT put the body or any heavy object on 

the device and do NOT operate the buttons or 

switches or connections with excessive force. 

Do NOT open 

• Please do NOT remove the cover of the equipment, 

otherwise you may get an electric shock. 
• Do NOT attempt to remove any internal component 

from the device, or to modify the equipment in 

whatever manner. In case of any abnormal condition, 

please stop using the device immediately and have it 

inspected and repaired by professional personnel. 

                     

   

Other Precautions 

• Our company shall not be responsible for data loss 

or damages due to improper use of unauthorized 

modification to the device. 

• The images and screen display in this Manual are 

only  for  description  and  may  be  different  from 

screen  images  in  actual  operation.  The  screen 

display depends on the product.

Summary of Contents for MAG2588

Page 1: ...MAG2588 Remote Paging Selector LEVEL dBV 3 0 3 8 13 CALL ALL User s Manual Welcome to use the DSPPA public address system Please read this manual carefully before using this device for your better use...

Page 2: ...system connection instruction product use instruction product specification and so on Please read this manual carefully before installation and use of the device Follow the instructions in the manual...

Page 3: ...source before they are connected to this product Please tune volume to its minimum level before the device is powered ON or OFF All terminals on the device marked with are live and dangerous and shou...

Page 4: ...nstructions 5 4 1 Start 5 4 2 Description of main menu 6 4 2 1 Display of time state 6 4 2 2 Partition status display 6 4 2 3 Partition paging operation 7 4 2 4 Grouping state display 7 4 2 5 Grouping...

Page 5: ...ign High fidelity and hand held dynamic microphone design Possess multi level level indication and the sound pressure is more intuitive Convenience for quick paging in emergencies with manual shortcut...

Page 6: ...one head indicator light Pin 2 is for voice signal input Pin 3 is empty Pin 4 is signal input ground terminal 5 Microphone connector Pin 4 is for Kalong socket one to one corresponding to 4 pins on th...

Page 7: ...n interface connected to MAG2189 host 7 Line audio output interface Connect the amplifier 8 Line audio input interface Connect the player device such as a DVD player or a tuner etc 9 Clock volume adju...

Page 8: ...f MAG2189 host 3 2 Connection of local interface of MAG2588 paging selector This paging selector can output audio signals The audio channel is used to connect the amplifier and speaker to achieve PA o...

Page 9: ...ne After power on it will enter the system initialization state and the paging selector screen will display the WELCOME Starting please wait During this process the system will load the last operation...

Page 10: ...ition button such as partition name the current task When the paging selector is connected to the system host the partition button displays green when it is not connected the partition button displays...

Page 11: ...s partition to end the paging the color changes to green When paging all partitions firstly select the partition page button on the upper right corner then touch the partition fully open to page all p...

Page 12: ...utton to select all groups to start paging Touch the Group fully closed button to stop paging Note After paging touch the small microphone icon on the upper right corner the microphone will be turned...

Page 13: ...the paging selector is automatically turned off Bell setting Select the bell Return return to the main menu 4 3 1 Time Setting Enter the System Setting menu touch the Time Setting icon to enter the sy...

Page 14: ...fy the password Users can self define the partition and group name and restore the default name after self defined For example modify the name of partition 1 to Grade One firstly check the partition s...

Page 15: ...ystem Setting menu touch the Microphone Setting button to enter the microphone auto off time setting interface Touch the time value or the circle at the front of the normally on state when the circle...

Page 16: ...Output 1V 50 10mV MIC distortion 1kHz 1V MIC 0 2 Effective range of MIC gain limits 3dB 100 12000Hz MIC SNR 30k low pass 68dB MIC AGC starting control threshold 600 50mV AUX Input Sensitivity Output...

Page 17: ...grid In case of any fault in the equipment the non professional person shall not disassemble the housing for repair without the approval in order to prevent accident or aggravate the damage to the eq...

Reviews: