Section 8: Programming Descriptions
41
Section [700] Automatic Clock Adjust
Program the number of seconds for the last minute of the day. This can be used to make minor corrections to the clock if the AC frequency is not
reliable. Valid entries are
[01]
to
[99]
.
Section [701] First International Options
The following attributes are available for PGM Output Type [09]
[1]
ON:
PGM output activates if a Service Required trouble condition is present.
[2]
ON:
PGM output activates if an AC trouble condition is present.
[3]
ON:
PGM output activates if a Telephone Line trouble condition is present.
[4]
ON:
PGM output activates if a Failure to Communicate trouble condition is present.
[5]
ON:
PGM output activates if a Zone Fault condition is present.
[6]
ON:
PGM output activates if a Zone Tamper condition is present.
[7]
ON:
PGM output will activates if a Wireless Low Battery trouble condition is present.
[8]
ON:
PGM output will activates if a Loss of Clock trouble condition is present.
The following attributes are available for PGM Output Type [10]
[1]
ON:
PGM output activates if a Burglary Alarm occurs.
[2]
ON:
PGM output activates if a Fire Alarm occurs.
[3]
ON:
PGM output activates if a Panic Alarm occurs.
[4]
ON:
PGM output activates if a Medical Alarm occurs.
[5]
ON:
PGM output activates if a Supervisory Alarm occurs.
[6]
ON:
PGM output activates if a Priority Alarm occurs.
[7]
ON:
PGM output will activates if a 24-Hour Duress Alarm occurs.
[8]
ON:
the PGM output activates for the time programmed for the PGM Output Timer.
OFF:
the PGM output will latch until a valid user code is entered.
Option
Description
[1]
ON: 50 Hz AC.
Configures the system for 50Hz AC.
OFF: 60 Hz AC.
Configures the system for 60Hz AC.
[2]
ON: Time Base Internal Crystal.
The system uses the internal crystal for the internal panel clock.
OFF:
Time Base AC-Line.
The system uses the AC frequency for the internal panel clock.
[3]
ON:
AC/DC Arming Inhibit with Battery Check Enabled.
The system will inhibit arming if a Low Battery or AC trouble
condition is present.
OFF:
Arming not Inhibited.
Arming will not be inhibited.
[4]
ON:
System Tampers Require Installer Reset
. All Tamper troubles will latch and arming will be inhibited. Enter Installer.
Programming to clear the trouble condition and return to normal operation.
OFF: System Tampers Do Not Require Installer Reset.
Tamper troubles will not latch and will not inhibit arming. Manual
bypassing of a zone will not bypass the tamper or fault states (DEOL).
[5]
ON: 6-digit Access Codes.
All access codes are 6 digits long.
OFF:
4-digit Access Codes.
All access codes are 4 digits long.
[6]
ON: Busy Tone Detection Enabled.
The system will hang up if a busy tone is detected. This attempt is not counted towards the
maximum dialing attempts.
OFF:
Busy Tone Detection Disabled.
The system will not detect busy tones.
[7]-[8] Future Use