Section 8: Programming Descriptions
The following is a brief description of the features and options available in the control panel.
Section [000] Keypad Function Key Programming
The five function keys can be reprogrammed with following functions. See Keypad Function Key Programming on page 15 for defaults
.
Section [001]-[002] Zone Definitions
Option
Description
Option
Description
[00]
Null Key:
Program non functioning keys with this option
[14]
Command Output #2:
See
[ ][7][1]
on page 12
[03]
Stay Arm:
See Stay Arm on page 10
[16]
Quick Exit:
See
[ ][0]
[04]
Away Arm:
See Away Arm on page 10
[17]
Reactivate Stay/Away Zones:
See
[ ][1]
[05]
No Entry Arm:
See
[ ][9]
on page 12
*
[27]
Disarm:
See Disarm on page 10
[06]
Chime On/Off:
See
[ ][4]
*
[29]
[A]ux Alarm:
Same as [A] key
[08]
Bypass:
See
[ ][1]
on page 10
*
[30]
[P]anic:
Same as [P] key.
[13]
Command Output #1:
See
[ ][7][1]
*
Applies to Key Fobs only (See Section [804] Subsection [61]-[76])
Option
Description
[00]
Null Zone:
Zone not used.
[01]
Delay 1:
When armed, provides entry delay when violated (follows Entry Delay 1).
[02]
Delay 2:
When armed, provides entry delay when violated (follows Entry Delay 2).
[03]
Instant:
When armed, instant alarm when violated.
[04]
Interior:
When armed, instant alarm if the zone is violated first, will follow entry delay if entry delay is active.
[05]
Interior Stay/Away:
Similar to ‘Interior’ except panel will auto-bypass the zone if armed in the Stay mode.
[06]
Delay Stay/Away:
Similar to ‘Delay 1’ except panel will auto-bypass the zone if armed in the Stay mode.
[07]-[08]
Future Use
[09]
24-Hour Supervisory (Hardwired):
Instant Alarm, silent at default.
[10]
24-Hour Supervisory Buzzer:
Instant alarm, panel will activate keypad buzzer instead of bell output.
[11]
24-Hour Burglary:
Instant alarm when violated, audible alarm at default.
[12]
Future Use
[13]
24-Hour Gas:
Instant alarm when violated, audible alarm at default.
[14]
24-Hour Heat:
Instant alarm when violated, audible alarm at default (also known as high-temp).
[15]
24-Hour Medical:
Instant alarm when violated, audible alarm at default.
[16]
24-Hour Panic:
Instant alarm when violated, audible alarm at default.
[17]
24-Hour Emergency:
Instant alarm when violated, audible alarm at default.
[18]
Future Use
[19]
24-Hour Water:
Instant alarm when violated, audible alarm at default (also known as flood).
[20]
24-Hour Freeze:
Instant alarm when violated, audible alarm at default (also known as low-temp).
[21]
Future Use
[22]
Momentary Keyswitch Arm:
Arms or disarms the system when violated.
[23]
Maintained Keyswitch Arm:
Arms system when violated, disarms system when restored.
[24]
For Future Use
[25]
Interior/Delay:
Function as an Interior zone when armed in Away mode, and as a Delay zone when armed in the Stay mode.
[26]
24-Hour Non-Alarm:
Zone will
NOT
create an alarm. Can be used with chime to identify a specific event.
[27]-[31]
Future Use
[32]
Instant Stay/Away:
Similar to ‘Instant’ except panel will auto-bypass the zone if armed in the Stay mode.
[33]-[35]
Future Use
[36]
24-Hour Non-Latching Tamper:
Instant tamper condition when violated. Active in armed and disarmed state.