Section [013] First System Options
Section [014] Second System Options
Section [015] Third System Options
Option
Description
[1]
ON:
Hardwired Zone 33 enabled.
OFF:
PGM1 Output enabled.
Program Zone Definition or PGM option in Section [009].
[2]
ON:
Hardwired Zone 34 enabled.
OFF:
PGM2 Output enabled.
Program Zone Definition or PGM option in Section [009].
[3]-[5]
Future Use
[6]
ON:
Audible Exit Fault Enabled.
If a delay zone is not secured correctly and not force-armed, at the end of the exit delay, the
system will go into entry delay and turn
ON
the bell output.
OFF: Audible Exit Fault Disabled.
The keypad will sound the entry delay through the keypad.
[7]
ON:
Event Buffer Follows Swinger Shutdown.
The system will
NOT
log additional alarms for a zone that has reached the swinger
shutdown threshold.
OFF: Event Buffer Logs Past Shutdown.
All zone alarms will be logged.
[8]
ON:
Temporal Three Fire Signal Enabled.
Temporal Three Fire Signal is used to annunciate fire alarms (½ second ON, ½ second
OFF, ½ second ON, ½ second OFF, ½ second ON, 1 ½ seconds OFF).
OFF:
Standard Pulsed Fire Signal.
The system will pulse the bell output (1 second ON, 1 second OFF).
Option
Description
[1]
ON:
Arm/Disarm Bell Squawk Enabled.
The system squawks the bell output once when the system is armed, twice when disarmed
and 3 times when disarming with alarms in memory.
OFF: Arm/Disarm Bell Squawk Disabled.
The bell output does not activate.
[2]
Future Use
[3]
ON:
RF Jam Logs after 5 Minutes.
The system logs an RF Jam trouble condition if the condition is present for 5 minutes.
OFF:
RF
Jam Logs after 20 Seconds.
The system logs the trouble condition after 20 seconds.
[4]
ON: Aux Boost Enabled:
When the system is in Power Save mode (AC Trouble) Aux+ output voltage is regulated 12VDC.
OFF: Aux Boost Disabled:
Aux+ output voltage is not regulated.
[5]
Future Use
[6]
ON:
Audible Exit with Urgency.
The system will beep the keypad once every second, and 3 times a second during the last 10
seconds, during exit delay when the system is armed with a user code or armed in the Away mode.
OFF:
Silent Exit Delay.
The keypad will not beep.
[7]
Future Use
[8]
ON: Fire Bell is Continuous.
The bell output will not time out if a fire alarm occurs. The User must turn off the bell by entering a
valid user code.
OFF: Fire Bell follows Bell Cut-off.
The bell output will time out normally.
Option
Description
[1]
ON: [F] Key Enabled.
The keypad
[F]
fire emergency key will be enabled.
OFF: [F] Key Disabled.
The keypad
[F]
fire emergency key will be disabled.
[2]
ON:
[P] Key Audible (Bell/Beeps).
The keypad
[P]
panic emergency will generate 3 ack beeps and the bell will activate for the
duration of the BTO or until a code is entered (keypad will display “System in Alarm”).
OFF:
[P] Key Silent.
The keypad
[P]
emergency key will generate a silent panic alarm. The bell will not sound and the keypad will
not display “system in alarm”.
[3]
ON: Quick Exit Enabled.
the Quick Exit feature will be enabled.
OFF: Quick Exit Disabled.
the Quick Exit feature will be disabled.
[4]
ON: Quick Arming Enabled.
The Quick Arming
[ ][0]
feature will be enabled.
OFF:
Quick Arming Disabled.
Quick Arming
[ ][0]
feature will be disabled.
If this feature is disabled, a valid user code must be entered after the Stay or Away function buttons are pressed.
[5]
ON: Code Required for Bypassing.
A valid user code must be entered after pressing
[ ][1]
to access the Bypass feature.
OFF:
No Code Required.
A user code is not required for bypassing.
[6]
ON: Master Code Not Changeable.
The Master Code (user code 40) can only be changed in Installer Programming.
OFF: Master Code Changeable.
The Master Code can be changed using the User Programming
[ ][5]
command.
[7]
ON:
TLM Enabled.
The system supervises the telephone line and displays a trouble if disconnected.
OFF:
TLM Disabled.
The telephone line is not supervised.
[8]
ON: System Tamper Enabled.
The panel will monitor the physical tamper switch, if the system is taken off the wall, or the front
housing is removed, a System Tamper Alarm will be generated.
OFF: System Tamper Disabled:
The panel will not monitor the physical tamper switch.