27
[03] Installer’s Code
(Section 4 “How to Program”)
Default
Default
1580
I_______I_______I_______I_______I
or
158000
I_______I_______I_______I_______II______I_______I
[04] Master Code
(Section 5.1 “Programming Security Codes”)
Default
Default
1234
I_______I_______I_______I_______I
or
123400
I_______I_______I_______I_______II______I_______I
[05] Second Master Code
(Section 5.1 “Programming Security Codes”)
Default
Default
AAAA
I_______I_______I_______I_______I
or
AAAA00
I_______I_______I_______I_______II______I_______I
[06] Programmable Terminals PGM 1 & 2
(Section 5.10 “PGM Output Options”)
Default
Default
02
I_______I_______I
PGM1
08
I_______I_______I
PGM2
Programmable Output Options
01
Ground Start Pulse
13
20 Minute Latched Alarm
02
Utility Output with Any Access Code
14
Line Seizure
([
✱
] [7] [1] + [Access Code])
15
Ready to Arm Status
03
Sensor Reset ([
✱
] [7] [2])
17
Downlook Support (PGM1 and PGM2 must be
04
Courtesy Pulse
programmed with 17)
05
Keypad Buzzer Follower Mode
25
For Future Use
06
System Armed Status
26
Momentary Key Switch Arm (PGM2 Only)
07
Strobe Output
27
Maintained Key Switch Arm (PGM2 Only)
08
Fail to Communicate / TLM Trouble Output
28
Silent 24 Hour (PGM2 Only)
09
Entry Delay Follower
29
Audible 24 Hour (PGM2 Only)
10
Exit Delay Follower
11
TLM and Alarm
12
Police Code Follower
[07] Keypad Lockout Options
(Section 5.20 “Keypad Lockout”)
Default
00
I_______I_______I
Number of Invalid Codes Before Lockout
00
I_______I_______I
Lockout Duration (in minutes)
[08] First System Option Code
Default
Option
ON
OFF
Section
OFF
I________I
1
Normally Closed Loops
End-of-Line Resistors
2.8
OFF
I________I
2
Double End-of-Line Resistors
Single End-of-Line Resistors
2.8
ON
I________I
3
[F] Key Enabled
[F] Key Disabled
5.14
OFF
I________I
4
[P] Key Audible Bell and Buzzer
[P] Key Silent Bell and Buzzer
5.14
ON
I________I
5
TLM Enabled
TLM Disabled
5.11
OFF
I________I
6
TLM Audible When Armed
TLM Trouble Only When Armed
5.11
[09] Second System Option Code
Default
Option
ON
OFF
Section
OFF
I________I
1
Master Code Not Changeable
Master Code Changeable
5.1
OFF
I________I
2
Code Required For Bypassing
No Code Required
5.1
OFF
I________I
3
6th Code is Duress Code
6th Code is Normal Code
5.1
OFF
I________I
4
Quick Exit Enabled
Quick Exit Disabled
3.4
OFF
I________I
5
Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
3.4
ON
I________I
6
AC Trouble Displayed
AC Trouble Not Displayed
3.4