26
G E T T I N G S T A R T E D
Keypad Programming
[00] Keypad Assignment
(Section 2.5 “Keypad Assignment”)
Note
:
This must be done at each keypad requiring programming.
[0] Slot (Valid entries are 11-18 for the Slot)
[1] - [5] Function Keys 1 to 5 Assignment (Valid entries are 00-18)
00
Null Key (Not Used)
07
[
✱
][6][——][4] System Test
13
[
✱
][7][1] Utility Output
01
Not used
08
[
✱
][1] Bypass Mode
14
[
✱
][7][2] Sensor Reset
02
Not used
09
[
✱
][2] Trouble Display
15
Not Used
03
Stay Arm
10
[
✱
][3] Alarm Memory
16
[
✱
][0] Quick Exit
04
Away Arm
11
[
✱
][5] User Programming
17
[
✱
][1] Reactivate Stay/Away’s
05
[
✱
][9] No-Entry Arm
12
[
✱
][6] User Functions
18
Not Used
06
[
✱
][4] Chime On / Off
Function
Function
Function
Function
Function
Slot (Address)
Key 1
Key 2
Key 3
Key 4
Key 5
1575RK defaults
11
–
–
–
–
–
PC5506T defaults
11
03
04
06
14
16
LCD5500T defaults
18
03
04
06
14
16
KEYPAD 1
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 2
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 3
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 4
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 5
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 6
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 7
I________I________I
I________I
I________I
I________I
I________I
I________I
KEYPAD 8
I________I________I
I________I
I________I
I________I
I________I
I________I
Zone Definitions
00
Null Zone (Not Used)
08
Standard 24 Hour Fire
17
24 Hour Emergency
01
Delay 1
10
24 Hour Supervisory Buzzer
18
24 Hour Sprinkler
02
Delay 2
11
24 Hour Burglary
19
24 Hour Water
2
03
Instant
12
24 Hour Heat
20
24 Hour Freeze
3
04
Interior
13
24 Hour Gas
21
24 Hour Latching Tamper
05
Interior, Stay/Away
14
24 Hour Hold-up
22
Interior Delay
06
Delay, Stay/Away
15
24 Hour Medical
23
24 Hour Bell Buzzer
nswer
07
Delayed 24 Hour Fire
16
24 Hour Panic
24
24 Push to Set
[01] Zone 1-6 Definitions
(Section 5.2 “Zone Definitions”)
Default
Default
01
I_______I_______I
Zone 1
03
I_______I_______I
Zone 4
06
I_______I_______I
Zone 2
03
I_______I_______I
Zone 5
03
I_______I_______I
Zone 3
03
I_______I_______I
Zone 6
[02] System Times
Default
[000-255]
030
I_______I_______I_______I
Entry Delay 1
045
I_______I_______I_______I
Entry Delay 2
120
I_______I_______I_______I
Exit Delay
004
I_______I_______I_______I
Bell Cutoff
Basic System Programming
P R O G R A M M I N G W O R K S H E E T S