13
H
O
W
V
T
O
V
P
R
O
G
R
A
M
light will turn OFF and the Armed light will turn ON.
Refer to Section 5 in this manual to determine what each
option represents and whether the light should be ON or
OFF for your application.
4.5 Viewing Programming
LED Keypads
Any programming section can be viewed from an LED
keypad. When a programming section is entered, the keypad
will immediately display the first digit of information
programmed in that section.
The keypad displays the information using a binary format,
where
Zone Light 1 = 1
Zone Light 2 = 2
Zone Light 3 = 4
Zone Light 4 = 8
Add up the values for the zone lights to determine the
number displayed (for example, no zone lights = 0, all 4
zone lights = 15 HEX ‘F’).
Press any of the Emergency Keys (Fire, Auxiliary or Panic)
to advance to the next digit. When all the digits in a section
have been viewed, the panel will exit the section; the Ready
Light will turn OFF and the Armed light will turn ON, waiting
for the next two digit programming section number to be
entered. Press the [#] key to exit the section
LCD Keypad
When a programming section is entered, the keypad will
immediately display all the information programmed in that
section.
Use the arrow keys (< >) to scroll through the data being
displayed.
Scroll past the end of the data displayed or press the [#] key
to exit the section.