5th System Option Code
Refer to Section
for programming instructions.
LIGHT
ON =
.
OFF =
ON =
. OFF =
ON =
. OFF =
ON =
l
OFF =
ON =
l
OFF =
ON =
. OFF =
Loss of AC will not cause an AC trouble
Loss of AC will cause AC
No siren during Auto-Arm
1 burst of siren every 10 seconds during Auto-arm pre-alert
Home-Away zones will have an entry delay when tripped
Home-Away zones act as interior when tripped
Quick-Exit is enabled
ignores one activation of a delay zone)
Quick-Exit is disabled
Auxiliary Delay zones can be force armed
Auxiliary Delay zones cannot be force armed
All zones except fire will be bypassed for 60 seconds upon power-up
All zones are active upon power-up
[R] “Ready” light; [A] = “Armed” light
l
Factory default
This feature must be enabled for UL installations.
Answering Machine
Double
Timer
Refer to Section
Light 3. Section
determines the acceptable length of time between
the first
and
second
calls when using the answering machine override feature.
Installer’s Lockout Enable
With this feature enabled, the Installer’s Code and Downloading Access Code will not be restored to the default
setting when the panel’s programming is restored to its default settings through a software or hardware reset.
This feature is designed to prevent tampering with the installer’s programming sections.
A control panel with this feature enabled will click its phone line relay 10 times upon power-up to indicate that
the Installer’s Lockout is enabled.
Ensure that the new Installer’s Code has been entered correctly before enabling this feature. There is no way
to re-entering the installer’s programming mode without the new Installer’s Code.
Installer’s Lockout Disable
Entering Section
when in the installer’s programming mode will disable the Installer’s Lockout feature.
NOTE:
Panels returned to DSC with the Installer’s Lockout feature enabled and no other apparent problems
will be subject to an additional service charge.