Utility Output Command
or
Code]
The Programmable Output (PGM terminal) can be programmed to be activated by a keypad command. This output
can be used to operate devices such as door
or special lighting. Depending on the option chosen, the
beentered.
and the PGM output will be activated for 5 seconds.
Programming Command
Code]
The PC1 150 is programmed from the keypad by using commands in the
section. These commands are
described in detail in the Programming Section of this manual. The default Installer’s Code is
Arming Without Entry Delay
Code]
Entering [
before entering an Access Code will arm the panel and remove the Entry Delay from the
delay zones.
All
will also be automatically bypassed. When armed using the
command, the “Armed”
light will FLASH to remind the user that the system is armed without the entry delay. This command allows the user
to remain at home and have an instant alarm on the entry doors.
Arming For
Night:
When retiring for the night, the user may reactivate bypassed interior “Home-Away” zones by entering the
command. When this command is entered, the “Armed” light will FLASH to remind the user that there is no entry
delay. The
command will not remove bypasses from zones that have been manually bypassed.
Quick-Exit:
when Armed
NOTE:
This feature must not be enabled on UL installations.
Entering
when the system is armed will allow the user to leave the premises through any delay zone
without altering the status of the system. This feature must be enabled for it to be operational; Quick-Exit may
be enabled at Section
Light 4.
After
is entered, only one armed delay zone may be opened within 2 minutes. Any additional openings,
or openings after the 2-minute delay will cause an alarm.
Keypad Zones
There are three zones which can be activated by pressing and holding two keys on the keypad. For these alarms
to be transmitted, the keypad zones must be enabled in Programming Section
Alarm and
Codes.
Press and hold
for 1 second to sound an alarm. A pulsed tone will sound, and the alarm will be
reported to
the
monitoring station if transmission is enabled. The keypad will sound a series of short beeps
once the panel has accepted the alarm.
Press and hold
for 1 second to generate a silent alarm alarm. The siren will not sound when this
function is activated. If programmed for transmission, the keypad will sound
a
series of short beeps upon
successful completion of the transmission to the monitoring station.
Press and hold
for 1 second togeneratean alarm. This alarm may be programmed
as
either silent
or audible. When programmed as audible, the siren will sound a steady tone: refer to Section
Light
6. Keypad audible annunciation for this alarm is programmable in Section
Light 5, as “audible”
(3 beeps) or “silent” (no buzzer feedback). If programmed as “audible”, the buzzer will sound once
the key input is accepted.
If the PC1 150 is armed and Zone 1 is a Delay zone, Zone 1 can be opened without an alarm sounding
if the Key is pressed and held before the zone is opened. This feature allows a door to be opened
without the system having to be disarmed. If Zone 1 is still open when the
Key is released, there
will be an instant alarm.