29
HOOKUP DIAGRAM
+
Battery Charge
Current is
360 mA Max
Pin 1
Pin 1
16VAC
40 VA min.
12 Volt 4 Ah
Gel-Cell
BA
TT
5A
m
p
AU
X
1A
m
p
BELL
5A
m
p
EEPROM
Reset
50 to 60Hz AC
LOAD
3
0
0
mA
MA
X
AUX
(+)
SIREN
12 Volt DC
1 Amp
Max.
NC
NO
NC
NC
End-of-Line
Resistor
1K 1/2W
EOL resistor
loop using
NO & NC
Devices
End-of-Line
Resistor
1K 1/2W
EOL resistor
loop using
NC devices
only
To
PGM
To
AUX
+
Smoke
Detector
Power
IN
OUT
N.O.
ALM
-
OUT
+
-
IN
+
BLK
WHT
RED
GRN
ULC-listed
latching 4-wire
smoke detector
(ESL model 446C)
End of Line Resistor
1k
Ω
1/2W
Refer to installation guidelines
when placing smoke detectors.
Alarm initiating
loop resistance
100 ohms
RM-1 Power loop
supervisory relay
12VDC 35mA max.
GRY
BRN RED
GRN
RJ31-X cord
RJ31-X
Telephone
Plug
PC1500RK
PC1500RKF
Keypad - 3 Max
Refer to the manual text
for detailed instructions
on keypad wiring.
AC
AUX +
BELL
+
PGM
KEYPAD
Z1
COM
Z2
Z3
COM
Z4
Z5
COM
Z6
R-1
T-1
RNG
TIP
YEL
GRN
WHT
Battery capacity for
emergency standby is
at least 4 hours if the
total load (BELL & AUX
output) is 800mA or
less. Recommended
battery is Yuasa
MNP4-12.
Do not connect transformer
to a receptacle controlled by
a switch.
Suggested Transformer:
Basler Electric
BE116240CAA-0002
For fire alarm applications, it is suggested that at least one indoor signalling appliance with a minimum 85dB rating and current rating
of 1 Amp or less be used (WHEELOCK model 34T-12-R rated 85dB(A) minimum for indoor residential applications).
Temperature Range: 0˚C to 47˚C (32˚F to 120˚F)
Maximum Humidity: 85% R.H.
Do not replace fuses with higher values than noted in this drawing.
Security detection devices that require power from control panel must operate over the voltage range of 10.0 to 14.0 VDC. The DSC
BRAVO series are recommended motion detectors.
BLK
RED
YEL GRN
pc15-cmd.cdr
JAN 7 1994