24
PC1500 Version 4.0
[16]
Zone Bypass Mask
Page 14
If the zone light is ON, the zone can be bypassed using the [
∗
][1] command. If a zone is defined as a fire zone,
it cannot be bypassed.
Default
ON
Zone Light 1
ON
Zone Light 2
ON
Zone Light 3
ON
Zone Light 4
ON
Zone Light 5
ON
Zone Light 6
[17]
System Times
Page 14
Default
0 3 0
Entry Delay (seconds)
1 2 0
Exit Delay (seconds)
0 0 4
Bell Cut-off (minutes)
0 3 0
AC fail transmission delay (minutes)
0 5 0
Slow zone response time ( × 10 ms)
0 3 0
Test transmission cycle or auto download cycle time (days)
Valid entries are “001” to “255”; do not enter “000”.
[18]
Auxiliary Delay Zone Entry/Exit Times
Page 15
Default
0 4 5
Entry Time (seconds)
1 2 0
Exit Time (seconds)
Valid entries are “001” to “255”.
[19]
System Clock Times
Page 15
Default
9 9 9 9
Automatic Arming (time of day)
9 9 9 9
Test transmission or auto download (time of day)
Enter 4 digits - “00” to “23” hours; “00” to “59” minutes. If not used, leave at default setting “9999”.
[20]
New Installer’s Code
Page 15
For Sections [20], [21] and [22]: Enter 4 digits from “0” to “9”. Do not enter [
∗
] or [#].
Default
1 5 0 0