26
PC1500 Version 4.0
[24]
Programmable Output Options (PGM Terminal)
Page 16
Enter 2 digits from “01” to “0C” only.
Default
0 4
Programmable Output
[01] Ground Start Pulse
[02] Utility Output, No Access Code - 5 seconds [
∗
] [7]
[03] Utility Output, Any Access Code - 5 seconds [
∗
] [7]
[04] 5 Second Reset Pulse [
∗
] [7]
[05] Courtesy Pulse (follows entry/exit times)
[06] Keypad Buzzer Follow Mode
∗
[07] System Status (arm/disarm) Output
[08] Strobe Output (latched alarm output)
[09] Failure to Communicate Output - follows trouble #4
[0A] PGM ON during Entry Delay
[0B] PGM ON during Exit Delay
[0C] LINKS1000 Interface
*****[06] Buzzer follows the Entry Delay, door chime, auto-arm alert
period and 24 hour buzzer zone.
[25]
Communicator Call Direction
Page 16
This section must be programmed completely. Do not press [#] to exit until all entries are completed.
Default
1
Zone Alarms and Restorals
1
Access Code Openings and Closings
1
Priority Alarms and Restorals
1
Maintenance Alarms and Restorals
[0] No transmissions for this group.
[1] Call 1st number and backup to 2nd number.*****
[2] Call 2nd phone number only.
[3] Always call both phone numbers.
*****Section [13] Light 1 “OFF” and 2nd phone number must be programmed.
[26]
Downloading Telephone Number
Page 17
This telephone number is used by the panel to call the downloading computer either by the periodic download
function or through the use of the [
∗
] [4] command.
Enter [0] for the digit ‘0’ in the phone number. Enter [
∗
4
∗
] (HEX D) for additional dial tone detection between
number digits, as in local PBX systems. Enter [#] to end the phone number entry.
[27]
Downloading Access Code
Page 17
Default
1 5 1 5
This code allows the panel to confirm that a valid downloading computer is requesting access to the panel.