DSC LINKS1000 Installation Manual Download Page 3

3

INTRODUCING THE

The LINKS1000 Cellular Alarm Transmitter enhances the protection provided by a security system by
providing a reliable backup to the control panel’s normal telephone communications with the monitoring
station. The LINKS1000 works with the DSC and Sur-Gard Security Control Panels described in the
Specifications below.

If the control panel is unable to complete an alarm transmission through the normal telephone line, due to any
line problems, the LINKS1000 will be activated and will transmit the alarm communication over the cellular
network. The LINKS1000 works automatically.

The LINKS1000 has been designed for simple and straightforward installation. Wiring connections are made
directly between the LINKS unit and the security control panel. The DSC and Sur-Gard Security Control Panels
require only minor changes in their Programming Sections

S p e c i f i c a t i o n s

Compatible control panels

• DSC PC1500/PC1550 software version 4.0 or later
• DSC PC1575/PC1580 software version 1.0 or later
• DSC PC2525 software version 1.0 or later
• DSC PC2550 software version 1.2 or later
• DSC PC3000 software version 7.6 or later
• DSC PC4010 software version 1.0 or later
• DSC PC4020 software version 1.0 or later
• DSC PC4020KT software version 1.0 or later
• DSC PC5010 software version 1.0 or later
• DSC PC5015 software version 2.2 or later (w/Downlook)
• DSC PC1555/PC1565/PC5008 software version 2.0 or later
• DSC PC580/PC585 software version 2.1 or later
• Sur-Gard DC1664LC software version 3.6 or later (requires MEX2 Module)
• Sur-Gard P16LC and P1664LC software versions 2.0 or later
UL has only verified compatibility with the PC4020 and PC5010.

Communication Method

• Amps cellular telephone network

RF Power Output

• 3.0 Watts maximum

Antenna

• 3 - 5 dB gain, TNC connector

Battery

• 12 volt 7 Ah minimum rechargeable gel-cell type battery

Transformer

• 16.5 V

AC

, 40 VA

Dimensions

• 11" × 11.8" × 3.3" (279 mm × 300 mm × 84 mm)

Weight

• 6.5 lbs. (3 kg)

IMPORTANT NOTE
A security system cannot prevent emergencies. It is only intended to alert you and, if included, a monitoring
station, of an emergency situation. Security systems are generally very reliable but they may not work under
all conditions and they are not a substitute for prudent security practices or life and property insurance. Your
security system should be installed and serviced by qualified security professionals who should instruct
you on the level of protection that has been provided and on system operations.

Summary of Contents for LINKS1000

Page 1: ...LINKS 12 Bat TBL Terminal 12 AC TBL Terminal 13 Battery Connections 13 Jumper J1 13 Jumper J2 13 HOOK UP DIAGRAM PC1500 1550 2525 2550 3000 1 4 HOOK UP DIAGRAM PC1575 PC1580 PC5010 PC5015 PC1555 PC156...

Page 2: ...lular service area only has two sides A or B The initial paging channel for Side A is 333 and for Side B is 334 System ID Also called the Home Access ID this 5 digit number identifies the customer s p...

Page 3: ...oftware version 7 6 or later DSC PC4010 software version 1 0 or later DSC PC4020 software version 1 0 or later DSC PC4020KT software version 1 0 or later DSC PC5010 software version 1 0 or later DSC P...

Page 4: ...e loss of current across T1 and R1 and sends the END key to the cellular network Telephone Line Monitor The Telephone Line Monitor is a separate feature integral to DSC or Sur gard control panels PC15...

Page 5: ...24 hour silent terminal and the Panic phone call will be connected through the cellular network Powering the LINKS1000 from a DC Source The LINKS1000 v3 0 and higher has the capability to be powered...

Page 6: ...ammer will automatically shut itself off if there is no keypad activity for a period of 2 minutes NOTE The LINKS1000 will not function until the Programmer is unplugged from it Programmer Low Battery...

Page 7: ...e pay close attention to the PREAMBLE Section when programming the control panel Using the LINKS1000 Programmer The LINKS1000 Programmer is used to enter the required cellular network parameters into...

Page 8: ...to the AC Tbl Sent screen and press Press the and keys to toggle either Enable or Disable Press to store and exit With the option Enabled the LINKS1000 WILL report loss of AC power With the option Dis...

Page 9: ...INKS Phone 0 LINKS Phone 1 System I D 1 ESN 2 Initial Page 2 System I D 3 Access Class 3 Initial Page 4 Downloading 4 Access Class 5 AC TBL Sent 5 Group ID Mark 6 Emergency Phone 6 Prefrd Sys Mark 7 D...

Page 10: ...not installed Before attaching the antenna first secure the TNC connector and cable attached to the LINKS unit in the hole in the top of the cabinet using the hardware provided Ensure the star washer...

Page 11: ...he designated LINKS supervision zone the control panel will report an open in the connection between the LINKS and the control panel see instructions for correct resistor value When using Normally Clo...

Page 12: ...r between these terminals PC1575 and PC1580 PGM2 configured for LINKS Answer allows downloading to be performed in the event of phone line failure When the LINKS receives a phone call it will activate...

Page 13: ...f line resistor MUST be used on this zone See hook up diagram for correct resistor value Battery Connections Do not connect the battery or the transformer until all other wiring is complete Connect th...

Page 14: ...nel to minimize the length of the wiring betweentheLINKS1000andthecontrol panel max 3ft apart 3 Depending on the security requirements of the installation the connections between the LINKS1000 and the...

Page 15: ...e the length of the wiring between the LINKS1000 and the control panel max 3ft apart 3 Depending on the security requirements of the installation the connections between the LINKS1000 and the control...

Page 16: ...the wiring between the LINKS1000 and the control panel max 3ft apart 3 Depending on the security requirements of the installation the connections between the LINKS1000 and the control panel may need t...

Page 17: ...o minimize the length of the wiring between the LINKS1000 and the control panel max 3ft apart 3 Depending on the security requirements of the installation the connections between the LINKS1000 and the...

Page 18: ...Cellular Communication trouble permanently secure the mounting bracket and antenna at the new location Before permanently mounting the LINKS1000 in it s final location verify that it is working as it...

Page 19: ...and they will always be dialed in front of the telephone number in the control panel memory Factory default of Preamble location is FFFF Program all unused digits as F If Lindsay Communications is use...

Page 20: ...nding alarms Minimal setting for LINKS operation is option 3 ON Section 52 Program Call Directions for tamper alarm and restorals Default is Disabled Section 53 Program Call Directions for Openings an...

Page 21: ...git as 0 to enable operations with the LINKS unit Section 55 Program a reporting code to enable the PC3000 to report Telephone Line Monitoring troubles to the monitoring station through the LINKS cell...

Page 22: ...elephone number should the land line fail the dial tone search Third Phone Number When the LINKS module is enabled this telephone number will be used to back up the third land line telephone number sh...

Page 23: ...on 009 This will reserve the PGM1 output for LINKS1000 communications Only PGM1 will support LINKS1000 operation Section 001 LINKS Supervisory 004 Choose the zone that will be used to report the 24 ho...

Page 24: ...ddress 06 Test Transmission Code and Forced Answer Zone First Two Digits Program a 2 digit reporting code to enable the Cellular Test Transmission Note that the regular Test Transmission must also be...

Page 25: ...unit ensure that the control panel is correctly programmed and operating properly by performing a test transmission to the monitoring station over the normal telephone line If problems are encountered...

Page 26: ...rk Add an extension antenna C Eight flashes means bad PGMIn connection This means the GND for the LINKS is not connected to a panel ground or the control panel is not programmed correctly Be sure the...

Page 27: ...al Trouble 30 seconds 8 flashes PGMIn Trouble 30 seconds AC Failure Loss of AC power to the LINKS1000 for more than 30 minutes is indicated by an AC failure Battery Fault A battery fault indicates tha...

Page 28: ...he LINKS1000 Step 2 Press any key on the Programmer to activate it Step 3 Select the Trouble menu item Step 4 The trouble items will be displayed NOTE For v2 x 2 1 and up only the most recent trouble...

Page 29: ...e m a t r i e l e s t conforme certaines normes de protection d exploitation et de s curit des r seaux de t l communications Industrie C a n a d a n a s s u r e t o u t e f o i s p a s q u e l e m a...

Page 30: ...damages loss of anticipated profits loss of time or any other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product WARNING SG Wireless Com...

Page 31: ...3 O W A R N I N G Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufactur...

Page 32: ...on of the terminal equipment Standard jacks shall be so arranged that if the plug connected thereto is withdrawn no interference to the operation of the equipment at the customer s premises which rema...

Reviews: