![DSC LINKS1000 Installation Manual Download Page 21](http://html1.mh-extra.com/html/dsc/links1000/links1000_installation-manual_2534878021.webp)
21
PC2550 Control Panel
The DSC PC2550 must be equipped with software version 1.2 or later.
Programming for all PC2550 software versions:
Section [30]
Program the 1st digit as [4] to enable the “forced answer” feature; otherwise do not change this
digit. Program the 2nd digit as [0] to enable operations with the LINKS unit.
Section [54]
Program a reporting code to enable the PC2550 to report Telephone Line Monitoring troubles
to the monitoring station through the LINKS cellular connection.
Section [55]
Program a reporting code to enable the PC2550 Cellular Test Transmission. Note that the
regular Test Transmission must also be enabled for the Cellular Test Transmission to operate.
Additional Programming for PC2550 v1.3 and later software:
Section [56]
LINKS Preamble (First Telephone Number). See preamble section for programming information.
Program all unused digits with hexadecimal “F”.
Section [57]
LINKS Preamble for Second Telephone Number.
Section [58]
LINKS Preamble for Downloading Telephone Number.
PC3000 Control Panel
The DSC PC3000 must be equipped with software version 7.6 or later.
Programming for all PC3000 software versions:
Section [28]
Program the 1st digit as [4] to enable the “forced answer” feature; otherwise do not change this
digit. Program the 2nd digit as [0] to enable operations with the LINKS unit.
Section [55]
Program a reporting code to enable the PC3000 to report Telephone Line Monitoring troubles
to the monitoring station through the LINKS cellular connection.
Section [56]
Program a reporting code to enable the PC3000 Cellular Test Transmission. Note that the
regular Test Transmission must also be enabled for the Cellular Test Transmission to operate.
Additional Programming for PC3000 v7.7 and later software:
Section [57]
LINKS Preamble (First Telephone Number). See preamble section for programming information.
Program all unused digits with hexadecimal “F”.
Section [58]
LINKS Preamble for Second Telephone Number.
Section [59]
LINKS Preamble for Downloading Telephone Number.
PC4010, PC4020 and PC4020KT Control Panels
NOTE: The DSC PC4010, PC4020 or PC4020KT control panel must be equipped with software version 1.0
or later.
LINKS Toggles
Yes:
LINKS module enabled. This selection must be enabled for the LINKS module to
operate with the PC4010/PC4020/PC4020KT
No:
LINKS module disabled
Note: Once the LINKS module is enabled, the Main PGM output is automatically
configured for LINKS operation and should not be used for any other function. The
PGM output cannot be reprogrammed until the LINKS module is deactivated.
Yes:
A test transmission is used for the LINKS module
No:
No test transmission is used for the LINKS module
Note: The LINKS Test Transmission Code is programmed in the Reporting Code Section
[0][04][3][10].