17
S
E
C
T
I
O
N
6
Additional Notes
6.1 Trouble Conditions
The control panel always watches for possible trouble conditions. If a trouble condition
occurs, the keypad “Trouble” light will turn on and the keypad will beep. Press [
✱
][2]
to display the trouble conditions.
The following trouble conditions apply to the receiver portion (identified as the
PC5132 by the panel) and/or any enrolled devices. For a description of all troubles,
please see your system
Installation Manual
.
• General System Tamper
• General System Supervisory
• Zone Fault
• Device Low Battery
• Zone Tamper
Wireless Zone Low Battery Transmission
Within the supervisory transmission, the device will indicate the status of the battery.
If a battery is low, the system will indicate a Device Low Battery trouble.
The system will delay reporting the event to the central station for the number of days
programmed for
Zone Low Battery Transmission Delay
in section [370]. This will
prevent unnecessary reporting of the event if the user has been instructed on how to
replace batteries.
6.2 Replacing Batteries in Wireless Devices
1
Remove the cover of the device from its backplate. This creates a tamper condition
on the zone.
2
Refer to the battery installation instructions on the
Installation Sheet
of each
component. Be sure to
note
the proper orientation of the batteries as you install
them.
3
When the fresh batteries are in place, re-attach the cover to the backplate. The tamper
is restored and the zone sends a battery trouble restoral signal to the receiver. The
battery trouble is now clear and the device should function normally.
NOTE: When batteries in one device need to be replaced, the batteries in all devices
should be replaced at the same time.