2
1.1 Unpacking
The LCD5501Z32-433 package includes the following par
The LCD5501Z32-433 package includes the following par
The LCD5501Z32-433 package includes the following par
The LCD5501Z32-433 package includes the following par
The LCD5501Z32-433 package includes the following parts:
ts:
ts:
ts:
ts:
• One LCD5501Z32-433 keypad
• One 5.6K Ohm resistor
• Four mounting screws
• One keypad inner door label
• One set of Fire, Auxiliary and Panic key labels
• One LCD5501Z User Sheet
• One LCD5501Z32-433 Installation Manual
1.2 Mounting
You should mount the keypad where it is accessible to designated points of entry
and exit. Once you have selected a dry and secure location, perform the following
steps to mount the keypad:
1. Remove the keypad backplate by loosening the screw located at the base of the
unit.
2. Secure the keypad backplate to the wall in the desired location. Use the screws
provided.
3. Before attaching the keypad to its backplate, complete the keypad wiring as
described in the next section.
1.3 Wiring
1. Before beginning to wire the unit, ensure that all power (AC transformer and battery)
is disconnected from the control panel.
2. Connect the four Keybus wires from the control panel (red, black, yellow and green) to
the keypad terminals (R B Y G). Consult the diagram below:
3. You can connect a device, such as a door contact, to the “Z” terminal of the LCD5501Z32-
433. This eliminates the need to run wires back to the control panel for the device. To
connect the zone, run one wire from the device to the Z terminal and the other wire from
the device to the B (black) terminal. For powered devices, run the red wire to the R
(positive) terminal and the black wire to the B (negative) terminal. When using end of
line supervision, connect the zone according to one of the configurations outlined in
your system’s