background image

Shock / Glass A djustment 

Use only during testing and setting

SHOCK

 - for adjustment of the

frequency sensitivity with
potentiometer “SHOCK”

SETTING - UP THE DETECTOR

PIR SENSITIVITY ADJUSTMENT: Switch 3 of DIP-4. Use for Setting ”PULSE” -

 provides sensitivity control of PIR according to the environment.

Position  Left  -  ”On”-  High  sensitivity

  For  stable  environments. 

Position  Right  -  ”OFF”-  Low  sensitivity

  For  harsh  environments.

“PIR CAL” POTENTIOMETER ADJUSTMENT: 

According to protected area range. Use the potentiometer marked 

“PIR CAL”

 to adjust the detection

sensitivity between 15% and 100% according to walk test in the protected area. (Factory setting is 57%). Rotate the potentiometer clockwise to increase
range, counter-clockwise to decrease range. Always walk test and re-adjust if required.

LED  IN DICATION  OF ALARM  SIGNAL:  Switch  1  of  DIP-4.  Use  for  Setting  “LED” 

-  provides  control  of  Alarm  signal  LED  indication.

Position Left - “On” 

- LED enable. 

Position Right “OFF”

 - LED disable.

SOUND SENSITIVITY ADJUSTMENT: Switch 2 of DIP-4. Use for Setting “AUDIO”

 - provides control of sound detection sensitivity. 

Position Left -

“On” 

-   reducing the sensitivity of sound detection by 50%. (Use in small room). 

Position Right “OFF”

 - Sensitivity of sound detection 100%.

PET  IMMUNITY  SETTING

Switch  4  of  DIP-4.

 

U se  for Setting  “PET”

  15kg  -  25kg. 

Position Left  “ON”

  Immunity  to  PET  up  to  15  kg.

Position Right “OFF”

 Immunity to PET up to 25 kg

TEST PROCEDURES

Wait for one minute warm up time after applying 12-Vdc power. Conduct testing with the protected area cleared of all people. Make sure to test the unit
thoroughly for proper detection.

Walk test: 1.

 Remove front cover.    Set 

“PULSE”

 to “ON” position, and set 

“LED”

 to 

“ON”

 position. 

2.

 Replace the front cover. 

3.

 Start walking slowly

across the detection area. 

4.

 Observe that the red led lights whenever motion is detected. 

5.

 Allow 5 sec. between each test for the detector to stabilize.

6.

 After the walk test is completed, you can set the 

“LED”

 to 

“OFF”

 position.

N OTE:

  Walk  tests  shoul d  be  conducted,  at  least  onc e  a  year,  to  confirm  proper   oper ation  and  coverage  of  the  detector.

ADJUSTMENT

GLASS

 - for adjustment of

the high frequency sensitivity
with potentiometer “GLASS”

NORMAL

 -

for regular
operation

Glass Break adjustment

To adjust the glass break sensitivity, place the jumper accordingly GLASS TEST marking. Green (SHOCK)
LED is constantly ON. Now you can adjust the sensitivity by rotating the GLASS CAL potentiometer. Operate
the Sound Break Simulator* near the protected window and rotate the potentiometer GLASS CAL clock-
wise to increase sensitivity, and counter-clock-wise to decrease sensitivity until the Yellow and Red LEDs
are illuminating for each glass break sound.

Note: 

When the jumper is set for GLASS adjustment, only the high frequency sound of breaking glass is

detected. 

*It  is  r ecommended  to  use  GLASS-BR EAK  Simulator  FG-701  (CROW  p/n  004001)

Shock Adjustment

To adjust the shock setting (increase/decrease sensitivity) place the jumper accordingly SHOCK TEST
marking - Yellow (GLASS) LED is constantly ON. Now you can adjust the sensitivity by rotating the potentiometer
SHOCK CAL.  Hit gently on the protected glass and rotate the potentiometer clock-wise to increase sensitivity,
and counter-clock-wise to decrease sensitivity until the Green and Red LEDs are illuminating for each hit.

Note: 

When the jumper is set for SHOCK adjustment, only the low frequency of the shock signal prior to

glass breakage is detected.

SHOCK/GLASS TEST PROCEDURE

Final Testing

*

 Make sure to set jumper “GLASS/SHOCK” in position NORMAL. When the jumper is in this position, the

detector will detect both shock and sound frequencies. 

*

 To ensure maximum protection against false alarms,

activate any device in the area, which might automatically cycle pumps, gene

Warm Up Period

 

60 sec

RFI Protection

 

30V/m  10 - 1000MHz

EMI Protection

 

50,000V of electrical interference from lighting

Visible Light
Protection

 

st able  ag ain st  halogen   light  2.4m  (8ft)or  reflec ted  ligh t

Detection range

Glass up to 10m (90

0

); PIR up to 15m (WA lens)

LEDs indicator 

Yellow LED (GLASS) 

- glass break signal for testing & adjustment

Green LED (SHOCK)

  -  shock  signal for testing &  adjustment

Red LED (ALARM)

 - alarm signal:

Fleshing light

 - glass & break detection or glass & shock & PIR

detection

Constant light 

- PIR detection

Dimensions

118mm x 62.5mm x 41mm (4.65” x2.46” x1.61”)

Weight

110 gr.

TECHNICAL SPECIFICATION

Detection Method

 

Quad (Four element) PIR & electret microphone

Detection Speed

0.15 - 3.6 m/sec

Power Input

 

8.2  - 16 Vdc

Current Draw

 

Alarm PIR :16.5mA; Alarm Shock & Glass 
22mA; Alarm all: 18mA
Standby:  16.5 mA

BI Directional
Temp.
Compensation

YES

Pulse Count

 

1,  AUTO

Alarm Period

 

2  sec

Alarm Output

 

N.C 28Vdc 0.1 A with 10 Ohm series protection 
resistors

Tamper Switch

 

N.C 28Vdc 0.1A with 10 Ohm series protection 
resistor - open when cover is remove

NO RMAL

GL ASS
TEST

SHOCK

TEST

GL ASS
TEST

SHOCK

TEST

NORMAL

NORMAL

GL ASS
TEST

SHOCK

TEST

BLOCK CONNECTOR

PYROSENSOR

SWI TCH FOR

SETTI NG S

FIG 8 

- PCB LAYOUT

LIMITED WARRANTY:

 

Digital Security Controls Ltd, warrants that  for a period of 12 months from the date of purchase, the product shall be free of defects  in materials and workmanship under normal use and that in fulfillment of any

breach of such war ranty. Digital Security Controls Ltd shall, at its option, repair or replace the defective equipment upon returns of the equipment to its repair depot. This warranty applies only to defects in parts and wor kmanship and not to
damage incurred in shipping or  handling, or damage due to causes beyond the control of Digital Security Controls Ltd, such as lightning, excessive voltage mechanical  shock, water  damage, or damage ar ising out of abuse, alteration or
improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether  expr essed or  implied and of all other obligations or liabilities on the part of Digital Secur ity Controls Ltd. Digital
Secur ity Contr ols  Ltd neither  assumes responsibility for, nor author izes any other person purporting  to  act on its behalf to modify or  to  change this warr anty, nor to assume  for  it  any other  warranty or  liability  concerning this pr oduct.
In no event shall Digital Secur ity Controls Ltd be liable for any direct, indirect or  consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or  operation
or failure of this product.
Motion detectors can only detect motion within the designated ar eas as Shown in their  respective installation instructions. They cannot discr iminate between intruders and intended occupants. Motion detectors do not pr ovide volumetric ar ea
protection. They have multiple beams of detection and motion can only be detected in unobstructed areas cover ed by these beams. They cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass
doors or windows. Any
type  of  tampering  whether  intentional  or  unintentional  such  as masking  ,  painting,  or  spraying  of  any  material  on  the  lenses,  mir rors,  windows  or   any  other  par t  of  the  detection system  will  impair   its  proper  oper ation.
Passive infrared motion detector s operate by sensing changes in temper ature. However  their effectiveness can be reduced when the ambient temperatur e rises near or above body temperatur e or if there ar e intentional or unintentional sources
of heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fir eplaces, sunlight, steam vents, lighting and so on.

WARNING: Digit al Security Controls Ltd, recommends that the ent ire syst em be completely tested on a regular basis. However, despite f requent testing, and d ue to, but not limited to, criminal tampering or elect rical disruption,
it is possible for this product to f ail to perf orm as expected.
Imp o rtan t   inf o rmat io n:   Ch ang es  o r  mo di fi cat ion s  n ot   exp ressl y  ap pro ved  by  D igi ta l  Secu rit y  Co nt rol s  Lt d   cou ld   voi d  t h e  use r's  au th ori ty   to   op erat e  t hi s  eq uip men t .

   2005 Digital Security Controls Ltd
Toronto, Canada

www.dsc.com

Reviews: