background image

Installation Instructions

LC-102PIGBSS

Professional Passive Infrared Shock & Glass Breakage
Detectors with Pet Immunity

A new generation  of  professional movement spread spectrum analyzing  PIR, Shock  & Glass Breakage  detectors.
The detector provides an analysis of environmental conditions through the entire movement spread frequency spectrum.

It listens for sounds of breaking glass, which produces two sequential signals of different frequencie “SHOCK”  and “GLASS”. The
unique phased frequency detection circuitry of this detector allows detection of both shock signal and the strong signal of glass
breakage creating a false alarm free detector. The detector does not need to be attached to the window, providing volume protection,
and allowing you to protect several windows with one detector.

FIG  2  

- Knockout h oles

FIG  1 - 

Bracket Installa tion

FIG 6 

- Lens pattern

Wall Mo unt
Br acket

Ceiling Mount
Br acket

FIG  3 

- Bracket options

1

2

C

C

A

B

B

B

B

A

A

D

D

C

C

C

TYPICAL INSTALLATION

Select mounting location

Choose a location in front of the protected windows, in direct line of sight within 4.5m. In case of more then one windo, place the detector in the center
area facing the windows, make sure that this location will be most likely to intercept an intruder, that may across the PIR beams. See PIR detection beams.
See SHOCK and GLASS detection area Fig.5,Fig.6. If heavy blinds or curtains cover the glass, you must locate the detector behind the blinds on the
window frame or above it, otherwise the blinds might block the sound.

Avoid the following locations: 

*

Facing direct sunlight. 

*

Facing areas subject with temperature changes. 

*

Areas with air ducts or substantial air flows.

*

Facing metal doors. 

*

Close to door entrance bells measuring 2” (or larger) in diameter.

MOUNTING DETECTOR BASE

1.

 To remove the front cover, unscrew the holding screw and gently raise the front cover Fig.4-11. 

2.

 To remove the PC board, carefully unscrew the holding

screw located on the PC board Fig.4-9. 

3.

  Break out the desired holes for proper installing Fig.2 B or C.  

4.

 The circular and rectangular indentations at

the bottom base are the knockout holes for wire entry. You may also use mounting holes that are not in use for running the wiring into the detector.(For
option with bracket - lead wire through the bracket, Fig4-7) 

5.

 Mount the detector base to the wall, corner or ceiling. ( For option with bracket install bracket)

Fig.1, Fig.3 

6.

 Reinstall the PC board by fully tightening the holding screw. Connect wire to terminal block. 

7.

 Replace the cover by inserting it back in

the appropriate closing pins and screw in the holding screw.

DETECTOR INSTALLATION

Terminal Block Connections 

(See Fig.7)

Terminals 1 & 2 - Marked “T1, T2” (TAMPER) 

If a Tamper function is required connect these terminals to a 24-hour normally closed protective zone in

the  control  unit.  If  the  fr ont  cover  of  the  detector  is  opened,  an  immediate  al ar m  signal  w ill  be  sent  to  the  control  uni t.

Terminals 3 & 4 - Marked “PIR: NC, C” 

These are the output PIR relay contacts of the detector. Connect to a normally closed zone in the control panel.

Terminal 5 - Marked “EOL” - 

End of line option.

Terminals 6 & 7 - Marked “MIC: NC, C” 

These are the output MICROPHONE relay contacts of the detector. Connect to a normally closed zone in the

control panel.

Terminal 8 - Marked “-” (GND)

 Connect to the negative Voltage output or ground of the control panel.

Termin al  9  -  Marked  “+”  ( +12V) 

Connect  to  a  positive  Voltage  output  of  8.2  -16Vdc  source  ( usually  from  the  alarm  control  unit)

FIG 4 

-  Detector Installa tion

FIG 7 

- Terminal block

FIG 5 

- Detector Mounnting

15m

11

6

5

8

4

10

9

1

3

7

1

2

3

4

5

6

7

8

9

T 2

EOL

- 12V +

MIC

NC

T 1

C

NC

C

PIR

1

3

Reviews: