1
The GS3060-RF is a wireless communicator that sends alarm system information to an SG-System III, SG-
System II, or SG-System I receiver through a GSM/GPRS wireless network. This wireless communicator can
be used with UL/ULC Listed compatible control units, as indicated in the manufacturer's installation
instructions.
NOTE: The GS3060-RF is designed to work with the Contact ID communication format as described in SIA
DC-05 Standard. Before completing the field installation of the alarm monitoring system please ensure
communication with the supervising central station is successful by sending several events and getting
confirmation that they have been received.
Features
• Compatible with 4-digit or 10-digit Contact ID communication format as described in SIA DC-05
Standard. Example of suitable compatible alarm panels: DSC Models PC1864, PC1832, PC1616,
PC4020.
• Simulates landline
• Switches automatically to the GSM network in the event of landline trouble (e.g., line down)
• GSM Signal Indicator
• Four programmable outputs
• Contains one 12V - 7 Ah battery
• Case Tamper Output
• Landline overvoltage protection
• Dual-band GSM radio
• Four programmable inputs
• GPRS/Internet communication with Sur-Gard System III / II / I
• Panel transmission monitoring for up to four phone numbers
Technical Specifications
The input voltage to the GS3060-RF is drawn from the power adaptor model DSC ADP1310-NAU (for
USA) and model DSC ADP1310-NA (for Canada).
NOTE
: The power supply must be Class II, Power Limited. For residential applications a suitable power
adaptor is model DSC ADP1310-NAU (for USA) and model DSC ADP1310-NA (for Canada).
Ratings
Power Supply Ratings - Input Voltage (for long-term operation)
JP3-OFF with internal battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . .13.8V
DC
required
NOTE: When the input voltage drops below 13.5Vdc the internal battery supplied with the
GS3060-RF will not be charged. In order to maintain a charged level for the internal battery, the
power supply must have a minimum voltage of 13.5Vdc to ensure a sufficient battery charge in
all conditions of use.
Current Consumption
JP3-OFF with internal battery: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120mA*
* Plus any current drawn from the GS3060-RF AUX+ terminal
Battery: . . . . . . . . . . . . . . sealed, rechargeable type, rated 12V/7Ah (for 24hr standby time)
Battery charging voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13.5V
DC
Battery charging current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50mA
NOTE: Battery must be replaced every 3-5 years.
Operating frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 850/1900MHz
Antenna gain: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0dBi
Environmental Specifications
Operating temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C-49°C (32°F-120°F)
Humidity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93%RH Maximum (non-condensing)
Mechanical Specifications
Dimensions (enclosure GS3060-RF): . . . . . . 130mm × 350mm × 107.5mm / 5.1” × 13.78” × 4.2”
Weight (without battery): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1433g / 3.16lbs
Simulated Telco Loop specifications (TIP/RING)
On-Hook Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35V
DC
Loop Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25mA
Loop Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 Ohms
INTRODUCTION
Summary of Contents for GS3060-RF
Page 2: ......