![DSC COMMUNIQUE VPM4580 Installation Manual Download Page 20](http://html1.mh-extra.com/html/dsc/communique-vpm4580/communique-vpm4580_installation-manual_2534382020.webp)
14
Assigning Items to Programmable
Outputs
You can assign an automation item to follow a
programmable output option.
For example, if you assign item 1 to output option (38)
Command Output 1, the item will activate or
deactivate whenever the user activates the command
output (e.g. using [*][7][1]).
Please refer to the PC4010/4020 Installation Manual
for a complete description of available programmable
output options.
To assign an item to a programmable output option:
1. At any system keypad, enter [*][8][Installer's code].
This takes you into the PC4010/4020 installer's
programming sections.
2. Enter reference number [000705]. (Refer to your
PC4010/4020 Installation Manual for instructions
on using reference numbers.)
3. Enter the 2-digit number of the automation item
you want to program (01-32).
4. Enter the 2-digit number of the programmable
output option you want the item to follow (00-58).
5. To save your programming and exit the section,
press [#].
NOTE
: Please see section 8, "Label Programming"
for a description of programming output control
labels for programmable output options (38)-(45)
Command Outputs 1-8.
Automation Item Pulse Timers
Program pulse times for automation items 01 to 32 in
programming sections [301] to [332]. Valid entries are
001 to 255 seconds.
Enable the Automation Pulse Times by turning OFF
option 06 in the Miscellaneous Options section for the
automation item (refer to programming section [131]
for more information).
firealarmresources.com