Maintenance 
 

Weekly 

Inspect the pump tube for signs of wear. 
Check doser output.  Adjust as necessary via the control screen. 

 
Monthly

 

 Replace pump tube monthly or sooner if any of the following occur: 

 

Sharply increased rate of dosing  

 

Split tube 

 

Each 6 Months

 

After disconnecting from electric supply, remove cover from Select-640 SSDIP doser and inspect interior 
of pump enclosure.  Ensure no ingress of moisture or other contaminant.  In case of difficulty, contact 
your supplier. 
 

 

Spare Parts and Accessories 
 

 
Item 

 

 
Code 

 

Select-640 SSDIP  Single Shot doser 

Unit 

010CA92 

 

 

 

Replacement pump tube pack – 5 tubes 

Grey 

011CA63/REP 

Replacement pump tube pack – 5 tubes 

Purple 

011CA48/REP 

Replacement pump tube pack – 5 tubes 

Brown 

011CA16/REP 

Delivery tube (low pressure)  6.0mm i.d. 

30m 

155CA60 

Delivery tube (low pressure)  4.8mm i.d. 

30m 

155CA48 

Delivery  tube (3m) plus end weight 

unit 

152CA05 

 

 

 

Quick-fit male/female connector 

unit 

153CA02 

 

 

 

Power supply 12V-DC 5A  UK style 

unit 

019CA00 

Power supply 12V-DC 5A  EU style 

unit 

019CA10 

 
 
 

Summary of Contents for Select-640

Page 1: ... www dosingsolutions com Contents Page 2 Quick fit instructions 2 Changing pump tubes 3 Pump tube life 3 Safety 3 Accuracy 3 Electrical supply 3 Operation screen controls 4 Constant pumping 5 Rotor Adjustment 5 Encoding 5 Installation 5 Problems errors 5 Maintenance 5 Power Resumption 6 Spare parts and accessories Select 640 Timed SSDIP ...

Page 2: ...be and power supply 12V DC 5A There are no user serviceable parts inside the Select 640 SSDIP doser The doser will also give the initial dose on power up Changing Pump Tubes ENSURE THE POWER SUPPLY IS DISCONNECTED BEFORE CHANGING THE PUMP TUBE OTHERWISE ROTOR TURNING IS POSSIBLE Removal of pump tube Remove the black pump cover 3 screws Unclip the pump tube at the inlet Lift out the pump tube whils...

Page 3: ...om the mains electricity supply A 5A maximum current power supply is recommended The Select 640 SSDIP doser normally runs below 2A although starting currents are larger and dependant on the pumping conditions encountered Operation When the electric supply is first connected the version of the programming will be shown This is the Welcome Screen Press Adjust to start the set up procedure If an Init...

Page 4: ...ey tube should be installed a Tube adjust of 6 has been entered there no timed doses recorded yet and the timer has 25 minutes remaining until the next timed dose The timer will run down to 00000 at which point the next timed dose will be given To make any adjustments to settings return to the Welcome Screen and progress through the options To return to the Welcome Screen press and hold Adjust fro...

Page 5: ...he pump can also be run dry without damaging any parts although it is not recommended to run the pump dry for extended periods Power Resumption On resuming power connection the doser will continue at the point where electrical power was lost The timer will continue as from the point where power was lost Pumping Problems Errors If the Select 640 SSDIP doser fails to operate correctly check the foll...

Page 6: ...f moisture or other contaminant In case of difficulty contact your supplier Spare Parts and Accessories Item Code Select 640 SSDIP Single Shot doser Unit 010CA92 Replacement pump tube pack 5 tubes Grey 011CA63 REP Replacement pump tube pack 5 tubes Purple 011CA48 REP Replacement pump tube pack 5 tubes Brown 011CA16 REP Delivery tube low pressure 6 0mm i d 30m 155CA60 Delivery tube low pressure 4 8...

Reviews: