background image

 

 

 

 

 

 
Remove the cover 
from the pump head 
(3 thumb screws). 

 
 
 
 
 

 

 

 

 

The pump is supplied 
(normally) with a 
beige coloured pump 
tube with a grey 
band, and also a 
spare pump tube for 
replacement. 
 
3m of PVC delivery 
tubing are also 
supplied with the 
pump.  
 
Cut the delivery tube 
to the desired lengths 
for inlet and outlet. 
 
Connect the delivery 
tube to the pump 
tube using the tube 
connectors provided. 
 

 

 

 
Place the tube clip in 
the pump head as 
shown.  This is 
important.  The clip 
should be in the 
housing above a 
mounting screw as 
shown. 
Turn the rotor by 
hand to load the tube 
– ensure the tube is 
fully inserted. 
 

CARE – MIND 

YOUR FINGERS

 

 

 

 

 

Replace the pump 
cover (3 thumb 
screws). 
 
Connect the pump to 
the 12V DC 5A 
transformer 
(supplied). 
 
The doser is ready to 
operate. 
 
See operation details 
below. 
 

 
 
Description 
 
The Select-640 Timed SSDIP is a dosing pump designed to give an initial dose of product, and then 
give subsequent doses of either the same or a different dosed at timed intervals.  The size of the initial 
dose, the size of the timed dosages and the timed interval (in minutes) are all selected from the on-
screen controls.  The components are; the main pump unit, delivery tube, and power supply (12V DC, 
5A).  There are no user serviceable parts inside the Select-640 SSDIP doser. 
 
The doser will also give the initial dose on power-up. 
 
Changing Pump Tubes

 

 

ENSURE THE POWER SUPPLY IS DISCONNECTED BEFORE CHANGING THE PUMP TUBE.   

OTHERWISE ROTOR TURNING IS POSSIBLE 

 

 

Removal of pump tube – Remove the black pump cover (3 screws).  Unclip the pump tube at the inlet.  
Lift out the pump tube whilst rotating the pump rotor by hand in a clockwise direction.  When the pump 
tube is clear of the rotors, completely remove the tube.  Pull the old (soft) pump tube from the tube 
connectors. 
 
Push the new pump tube onto the tube connectors WITH THE TUBE RESTRAINT (ZIP TIE) ON THE 
INLET SIDE.  See instructions (above) to install new tube in the pump-head.

 

 
Ensure that all connectors between the pump tube and delivery tubes are securely fitted.  If necessary 
warm the delivery tube with warm air or water to soften it to make fitting more easy. 
 
Pump Tube Life 
The life of the pump tube will depend on many factors including the product being dosed, the back 
pressures under which the pump is working, and the amount of time the pump needs to run to perform 
correctly.  It is suggested that, in order to maintain dosing accuracy, the pump tube is replaced on a BI-
MONTHLY BASIS or sooner if wear or disfiguration of the tube is apparent.  Spare tubes are available 

Summary of Contents for Select-640

Page 1: ... www dosingsolutions com Contents Page 2 Quick fit instructions 2 Changing pump tubes 3 Pump tube life 3 Safety 3 Accuracy 3 Electrical supply 3 Operation screen controls 4 Constant pumping 5 Rotor Adjustment 5 Encoding 5 Installation 5 Problems errors 5 Maintenance 5 Power Resumption 6 Spare parts and accessories Select 640 Timed SSDIP ...

Page 2: ...be and power supply 12V DC 5A There are no user serviceable parts inside the Select 640 SSDIP doser The doser will also give the initial dose on power up Changing Pump Tubes ENSURE THE POWER SUPPLY IS DISCONNECTED BEFORE CHANGING THE PUMP TUBE OTHERWISE ROTOR TURNING IS POSSIBLE Removal of pump tube Remove the black pump cover 3 screws Unclip the pump tube at the inlet Lift out the pump tube whils...

Page 3: ...om the mains electricity supply A 5A maximum current power supply is recommended The Select 640 SSDIP doser normally runs below 2A although starting currents are larger and dependant on the pumping conditions encountered Operation When the electric supply is first connected the version of the programming will be shown This is the Welcome Screen Press Adjust to start the set up procedure If an Init...

Page 4: ...ey tube should be installed a Tube adjust of 6 has been entered there no timed doses recorded yet and the timer has 25 minutes remaining until the next timed dose The timer will run down to 00000 at which point the next timed dose will be given To make any adjustments to settings return to the Welcome Screen and progress through the options To return to the Welcome Screen press and hold Adjust fro...

Page 5: ...he pump can also be run dry without damaging any parts although it is not recommended to run the pump dry for extended periods Power Resumption On resuming power connection the doser will continue at the point where electrical power was lost The timer will continue as from the point where power was lost Pumping Problems Errors If the Select 640 SSDIP doser fails to operate correctly check the foll...

Page 6: ...f moisture or other contaminant In case of difficulty contact your supplier Spare Parts and Accessories Item Code Select 640 SSDIP Single Shot doser Unit 010CA92 Replacement pump tube pack 5 tubes Grey 011CA63 REP Replacement pump tube pack 5 tubes Purple 011CA48 REP Replacement pump tube pack 5 tubes Brown 011CA16 REP Delivery tube low pressure 6 0mm i d 30m 155CA60 Delivery tube low pressure 4 8...

Reviews: