Contents 

 
Page 
 

 

Quick-fit instructions 

Changing pump tubes  

Pump tube life 

Safety  

Accuracy  

Electrical supply  

Operation – screen controls 

Constant pumping 

Rotor Adjustment 

Encoding  

Installation  

Problems / errors  

Maintenance 

Power Resumption 

Spare parts and accessories 

 

 

 

 

 

 

 

 

 

 

 

 

Select-640 Timed SSDIP 

 

 

 

Summary of Contents for Select-640

Page 1: ... www dosingsolutions com Contents Page 2 Quick fit instructions 2 Changing pump tubes 3 Pump tube life 3 Safety 3 Accuracy 3 Electrical supply 3 Operation screen controls 4 Constant pumping 5 Rotor Adjustment 5 Encoding 5 Installation 5 Problems errors 5 Maintenance 5 Power Resumption 6 Spare parts and accessories Select 640 Timed SSDIP ...

Page 2: ...be and power supply 12V DC 5A There are no user serviceable parts inside the Select 640 SSDIP doser The doser will also give the initial dose on power up Changing Pump Tubes ENSURE THE POWER SUPPLY IS DISCONNECTED BEFORE CHANGING THE PUMP TUBE OTHERWISE ROTOR TURNING IS POSSIBLE Removal of pump tube Remove the black pump cover 3 screws Unclip the pump tube at the inlet Lift out the pump tube whils...

Page 3: ...om the mains electricity supply A 5A maximum current power supply is recommended The Select 640 SSDIP doser normally runs below 2A although starting currents are larger and dependant on the pumping conditions encountered Operation When the electric supply is first connected the version of the programming will be shown This is the Welcome Screen Press Adjust to start the set up procedure If an Init...

Page 4: ...ey tube should be installed a Tube adjust of 6 has been entered there no timed doses recorded yet and the timer has 25 minutes remaining until the next timed dose The timer will run down to 00000 at which point the next timed dose will be given To make any adjustments to settings return to the Welcome Screen and progress through the options To return to the Welcome Screen press and hold Adjust fro...

Page 5: ...he pump can also be run dry without damaging any parts although it is not recommended to run the pump dry for extended periods Power Resumption On resuming power connection the doser will continue at the point where electrical power was lost The timer will continue as from the point where power was lost Pumping Problems Errors If the Select 640 SSDIP doser fails to operate correctly check the foll...

Page 6: ...f moisture or other contaminant In case of difficulty contact your supplier Spare Parts and Accessories Item Code Select 640 SSDIP Single Shot doser Unit 010CA92 Replacement pump tube pack 5 tubes Grey 011CA63 REP Replacement pump tube pack 5 tubes Purple 011CA48 REP Replacement pump tube pack 5 tubes Brown 011CA16 REP Delivery tube low pressure 6 0mm i d 30m 155CA60 Delivery tube low pressure 4 8...