Pump Tube Colour 

 

Priming pump rate 

Grey 

72 litres / hour 

Purple 

36 litres / hour 

Brown 

4.92 litres / hour 

 
It is not recommended to use the Select-640 SSDIP doser for more than 2 hours at a time in the priming 
mode, as tube and motor life will be reduced. 
 
Rotor Adjustment 
The rotors in the Select-640 SSDIP  pump-head are not adjustable. 
 
Encoding 
Under the rotor assembly, there is a magnet holder plate that turns with the rotor on the drive shaft.  
This plate should be fitted so that the magnets are uppermost.  The translucent washer should be under 
the magnet holder plate. 
 
Installation 
The Select-640 SSDIP doser can be powered from a 12V DC battery or via a transformer from the 
mains electricity supply.  Position the dosing point so as to be convenient for a power source if power is 
to be taken via a transformer from the mains.  Ensure that the Select-640 SSDIP doser is properly 
secured to prevent it becoming immersed in water or stock solution. 
 
Connect the Select-640 SSDIP  doser to either battery or transformer.  Choose program options from 
the control screen.  Ensure pump tube fitted and connected to inlet and outlet delivery tubes.  Place inlet 
tube weight into additive liquid.  Position the outlet tube to dose in the desired location.   
 
Note:  The pump will self prime.  The pump can also be run dry without damaging any parts although it 
is not recommended to run the pump dry for extended periods. 
 
Power Resumption 
On resuming power connection, the doser will continue at the point where electrical power was lost. The 
timer will continue as from the point where power was lost. 
 
Pumping Problems / Errors 
If the Select-640 SSDIP  doser fails to operate correctly, check the following: (If the problem can not be 
resolved – contact your Distributor) 
 

 
Problem 

 
Solution 

 

Incorrect dosing. 

1. 

Check for low battery power If external battery is in 
use) 

2. 

Pump tube should be replaced regularly. Replace if 
necessary 

3. 

Is correct dosing amount selected? 

4. 

Water pressure in the drinking water line should not 
exceed 2 bar.  Fit pressure reduction device if 
necessary. 

5. 

Incorrect Tube Adjust Factor entered on the control 
screen.  Check and re-enter. 

6. 

Incorrect pump tube fitted.  Are screen details 
correct? 

 

Product not being pumped from stock container. 

1. 

Check all tube connections are firmly in place. 

2. 

Inlet tube could be blocked.  Clear as necessary. 

3. 

If a knife has been used to free a tube connector on 
the inlet side of the pump, the connector could be 
damaged and letting air into the suction line. 

 

Sudden loss of pumping pressure (with possible 
return of fluid into stock container) 

Check if there is any lateral movement in the rotor.  
It is possible the rotor shaft bearings may have 
worn.  Consult Distributor. 

Check for physical damage to pump head fixing 
screws.   

 

 
 

Summary of Contents for Select-640

Page 1: ... www dosingsolutions com Contents Page 2 Quick fit instructions 2 Changing pump tubes 3 Pump tube life 3 Safety 3 Accuracy 3 Electrical supply 3 Operation screen controls 4 Constant pumping 5 Rotor Adjustment 5 Encoding 5 Installation 5 Problems errors 5 Maintenance 5 Power Resumption 6 Spare parts and accessories Select 640 Timed SSDIP ...

Page 2: ...be and power supply 12V DC 5A There are no user serviceable parts inside the Select 640 SSDIP doser The doser will also give the initial dose on power up Changing Pump Tubes ENSURE THE POWER SUPPLY IS DISCONNECTED BEFORE CHANGING THE PUMP TUBE OTHERWISE ROTOR TURNING IS POSSIBLE Removal of pump tube Remove the black pump cover 3 screws Unclip the pump tube at the inlet Lift out the pump tube whils...

Page 3: ...om the mains electricity supply A 5A maximum current power supply is recommended The Select 640 SSDIP doser normally runs below 2A although starting currents are larger and dependant on the pumping conditions encountered Operation When the electric supply is first connected the version of the programming will be shown This is the Welcome Screen Press Adjust to start the set up procedure If an Init...

Page 4: ...ey tube should be installed a Tube adjust of 6 has been entered there no timed doses recorded yet and the timer has 25 minutes remaining until the next timed dose The timer will run down to 00000 at which point the next timed dose will be given To make any adjustments to settings return to the Welcome Screen and progress through the options To return to the Welcome Screen press and hold Adjust fro...

Page 5: ...he pump can also be run dry without damaging any parts although it is not recommended to run the pump dry for extended periods Power Resumption On resuming power connection the doser will continue at the point where electrical power was lost The timer will continue as from the point where power was lost Pumping Problems Errors If the Select 640 SSDIP doser fails to operate correctly check the foll...

Page 6: ...f moisture or other contaminant In case of difficulty contact your supplier Spare Parts and Accessories Item Code Select 640 SSDIP Single Shot doser Unit 010CA92 Replacement pump tube pack 5 tubes Grey 011CA63 REP Replacement pump tube pack 5 tubes Purple 011CA48 REP Replacement pump tube pack 5 tubes Brown 011CA16 REP Delivery tube low pressure 6 0mm i d 30m 155CA60 Delivery tube low pressure 4 8...

Reviews: