background image

 

 

Press Set to get to the next screen. 
 
 
This screen shows that the Timed dose is 1000ml, and the Grey 
pump tube should be used. 
 
Press set. 
 
 

 

 
A Tube Adjust % figure will be shown on the packet that the 
pump tube was supplied in.  Use the Adjust button to scroll 
through (-20% to +20%) until the correct figure is shown 
 
This feature can also be used to trim the output of the pump.  
Then press set. 
 

 

 
The Select-640 SSDIP  SSDIP will display the number of timed 
doses that have been produced.  This figure can be reduced to 
zero on this screen. 
 
Then press Set. 

 

 
If you need to fill up the delivery tube with product, press Yes, 
the pump will turn continuously and show Priming… on the 
screen.  Press Stop when required. 

 

 
As soon as the priming phase is ended, the initial dose is made 
showing the screen on the right. 
 
Once this dose is completed, the following screen is shown: 

 

 
This is the normal dosing screen.  The timed dose is 1000ml, 
the Grey tube should be installed, a Tube adjust of +6% has 
been entered, there no timed doses recorded yet, and the timer 
has 25 minutes remaining until the next timed dose. 
 
The timer will run down to 00000 at which point the next timed 
dose will be given. 
 

 

 

 
To make any adjustments to settings, return to the Welcome Screen and progress through the options.  
To return to the Welcome Screen, press and hold 

Adjust

 from the Operational Screen. 

 
On the Operational Screen, the following colour abbreviations are used for pump tubes: 
 

Grey 

Gry 

Purple 

Ppl 

Brown 

Brn 

 
Constant Pumping 
If the priming option is selected from the menu on the control screen (see above) the pump rotor will turn 
continuously

 

regardless of the flow in the drinking line.  This can be useful for filling the suction and 

delivery lines prior to proportional dosing.  It can also be used if a particular product needs to be dosed 
quickly within a given period.  The following pumping rates will be achieved when the Select-640 SSDIP 
doser is set to “prime”: 
 

1000 

Use Grey tube

 

Zero dose count? 

 

No                  Yes  

Adjust % 

 

+6 

Prime pump? 

 

No                  Yes  

Dosing… 

 

Int dose 12000  

 

0N               00025  

Summary of Contents for Select-640

Page 1: ... www dosingsolutions com Contents Page 2 Quick fit instructions 2 Changing pump tubes 3 Pump tube life 3 Safety 3 Accuracy 3 Electrical supply 3 Operation screen controls 4 Constant pumping 5 Rotor Adjustment 5 Encoding 5 Installation 5 Problems errors 5 Maintenance 5 Power Resumption 6 Spare parts and accessories Select 640 Timed SSDIP ...

Page 2: ...be and power supply 12V DC 5A There are no user serviceable parts inside the Select 640 SSDIP doser The doser will also give the initial dose on power up Changing Pump Tubes ENSURE THE POWER SUPPLY IS DISCONNECTED BEFORE CHANGING THE PUMP TUBE OTHERWISE ROTOR TURNING IS POSSIBLE Removal of pump tube Remove the black pump cover 3 screws Unclip the pump tube at the inlet Lift out the pump tube whils...

Page 3: ...om the mains electricity supply A 5A maximum current power supply is recommended The Select 640 SSDIP doser normally runs below 2A although starting currents are larger and dependant on the pumping conditions encountered Operation When the electric supply is first connected the version of the programming will be shown This is the Welcome Screen Press Adjust to start the set up procedure If an Init...

Page 4: ...ey tube should be installed a Tube adjust of 6 has been entered there no timed doses recorded yet and the timer has 25 minutes remaining until the next timed dose The timer will run down to 00000 at which point the next timed dose will be given To make any adjustments to settings return to the Welcome Screen and progress through the options To return to the Welcome Screen press and hold Adjust fro...

Page 5: ...he pump can also be run dry without damaging any parts although it is not recommended to run the pump dry for extended periods Power Resumption On resuming power connection the doser will continue at the point where electrical power was lost The timer will continue as from the point where power was lost Pumping Problems Errors If the Select 640 SSDIP doser fails to operate correctly check the foll...

Page 6: ...f moisture or other contaminant In case of difficulty contact your supplier Spare Parts and Accessories Item Code Select 640 SSDIP Single Shot doser Unit 010CA92 Replacement pump tube pack 5 tubes Grey 011CA63 REP Replacement pump tube pack 5 tubes Purple 011CA48 REP Replacement pump tube pack 5 tubes Brown 011CA16 REP Delivery tube low pressure 6 0mm i d 30m 155CA60 Delivery tube low pressure 4 8...

Reviews: