Dryer Master
A
M
3
Product Manual
©
Dryer Master Inc.
Page: 25
4.2.6 Auto Setup
–
Rate Selection Mode C
Press the “
Touch area
” <
Normal Rate
> to display the numeric
touch pad data entry s
creen for setting the “Normal” running
speed.
Press the “
Touch area
” <
% Rate Change
> to display the numeric
touch pad data entry screen for setting the % Rate Change. This
the difference value from the “Normal Rate” as a percent of the
normal rate.
In thi
s example, “Normal rate” + “% Rate Change” = “High Rate”, 50
+ (50/100*10) = 55 and “Normal rate”
-
“% Rate Change” = “Low
Rate”, 50 –
(50/100*10) = 45
Press the “
Touch area
” <
Exit
> to return to the Main screen.
Figure 27.
–
Auto Setup
–
Rate selection Mode C
Press the “
Touch area
” <
Back
> to return to the previous menu
screen.
3)
Mode C:
a.
Events are identical to Mode A. and B
b.
If an adjustment is require to the normal or primary operating speed the High and Low
speed settings will also change by the programmed offset. In this case this offset is
dynamic because it is a percentage of the normal or primary running speed. Therefore
the amount of change will be smaller at lower speeds and larger for higher speeds thus
reducing the input required by the user.
The system will cycle between the speed settings triggered by the moisture target and limits. In
Mode C the normal or primary speed is manually set, as well as the moisture target and limits, and
the delay time and possibly a tweak of the speed offset percentage.
4)
All modes will require some tuning to optimize the system operation. Different dryers and
different products will require slightly different operating parameters. The default parameters
should allow the system to operate and provide good results. Adjusting the moisture targets
and limits and finding the optimum speed offsets for your application should allow the system
to maintain very good moisture control.
5)
The key is to maintain the normal running rate settings where it needs to be and provide a
sufficient window with the high and low rate change settings to allow the system to operate
effectively.
SYSTEM
F1
F2
F3
F4
Exit
Normal Rate
50.00
% Rate Change
10.0%
Back
Summary of Contents for AM3
Page 1: ......
Page 84: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 82 11 Appendix C IMO Set up Guide ...
Page 85: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 83 ...
Page 86: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 84 ...
Page 87: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 85 ...
Page 88: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 86 ...