Page: 71
8.1.4 Bypass Chute screw metering RPM table
Metering Device
Approximate rpm.
Gear Reduction for 1750
rpm Motor
6” screw conveyor standard
pitch
6.5
270:1
6” screw conveyor ½ pitch
13
135:1
4” screw conveyor standard
pitch
20
88:1
4” screw conveyor ½ pitch
40
44:1
4” flex screw conveyor
20
88:1
Figure 98.
–
Table of metering device RPM
–
screw conveyor
Note: When using a screw conveyor as the product-metering device it is recommended that the screw
section under the moisture sensor chute be made ½ pitch. This ensures the conveyor is only ½ full
once the screw returns to normal pitch reducing mechanical wear, product damage and motor/gearbox
load requirements.
!
Note:
!
Placement at the feed end ensures maximum product flow at the sensor. Leave
sufficient space between the conveyor and the sensor to ensure a plug flow at the
sensor.