4.2.4 Auto Setup
–
Rate Selection Mode A
Press the “
Touch area
” <
Normal Rate
> to display the numeric
touch pad data entry screen for setting the “Normal” running
speed.
Press the “
Touch area
” <
High Rate
> to display the numeric
touch pad data entry screen for setting the High Rate speed. This
is the speed the system will run will moisture is below the “Low
Moist. Limit”
Press the “
Touch area
” <
Low Rate
> to display the numeric
touch pad data entry screen for setting the Low Rate speed. This
is the speed the system will run will moisture is above the “High
Moist. Limit”
Figure 25.
–
Auto Setup
–
Rate selection Mode A
Press the “
Touch area
” <
Exit
> to return to the Main screen.
Press the “
Touch area
” <
Back
> to return to the previous menu
screen.
1)
Mode A:
a.
An event happens and the moisture drifts away from target.
b.
The moisture goes high. The moisture goes above the High limit target occasionally but
nothing happens. Note, there is a timer that is triggered anytime the moisture goes
above the high limit target or low limit target.
c.
Once the moisture stays above the High limit target for the programmed length of time
(default is 300 seconds = 5 minutes). The low speed setting is activated.
d.
The system will now operate at this slower speed setting until the moisture is once
again below the High limit target.
e.
When the moisture has been below the High moisture target for the programmed
length of time (default is 300 seconds = 5 minutes) system will return to the normal or
primary speed.
f.
A second event happens and the moisture again drifts away from target
g.
This time the moisture goes dry. The moisture goes below the Low limit target. Again
the moisture has to stay below the Low limit target for the programmed length of time
(default is the same 300 seconds = 5 minutes)
h.
Once the moisture stays below the Low Limit target for the programmed length of time
(default is 300 seconds = 5 minutes). The high speed setting is activated.
i.
The system will now operate at this higher speed setting until the moisture is once
again above the Low limit target.
j.
When the moisture has been above the Low moisture target for the programmed
length of time (default is 300 seconds = 5 minutes) system will return to the normal or
primary speed.
The system will cycle between the speed settings triggered by the moisture target and limits. In
Mode A all 3 speeds are manually set, as well as the moisture target and limits, and the delay time.
SYSTEM
F1
F2
F3
F4
Exit
High Rate
55.00
Normal Rate
50.00
Low Rate
45.00
Back
Summary of Contents for AM3
Page 1: ......
Page 84: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 82 11 Appendix C IMO Set up Guide ...
Page 85: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 83 ...
Page 86: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 84 ...
Page 87: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 85 ...
Page 88: ...Dryer Master AM3 Product Manual Dryer Master Inc Page 86 ...