10.4 Redox Calibration
10.44
10.45
redoX
10.43
10.42
10.41
The redox value shows the oxidation/reduction potential and is used to determine the sterility of the water. Adjusting the ideal redox level (setpoint) is the last step in the
system start up sequence.
Redox control
10.41
Calibration of the redox probe:
Recommended at least every 2 to 3 months.
10.42
Calibration with buffer
(buffer
solution 465 mV): Follow the instructions
that appear on the display
10.44
Manual calibration:
Not recommended!
10.5 Conductivity calibration
10.52
10.53
10.51
10.54
10.55
1
2
Metering and control of the
conductivity of the water in
μ
S
Optional Conductivity probe
10.51
Calibration of the Conductivity probe:
Recommended every month during usage season.
10.52
Calibration with buffer
(buffer solution 1413 μS/
12880 μS/ neutro): Follow the instructions in 7 steps that
appear in the display (screen 4.24 corresponds to step 1).
10.54
Manual calibration:
Not recommended!
Conductivity probe
1
yellow
2
transparent
11. VARIABLE SPEED PUMP
11.1
11.2
11.4
11.3
110-230 V
max. 3.15 A
POTENTIALFREIE KONTAKTE
1 2 3 4 5 6
7 8 9
10 11 12 13 14
14
12
11
A1 A2
L
N
11.1
Variable Speed Pump:
To install a Variable Speed Pump
contact your installer.
11.2 - 11.5
After connecting the pump, each filtration period
can be assigned a different speed
F
: fast,
M
: medium and
S
: slow.
See chapter 12 - Filtration
11.5
Filter cleaning:
To backwash the filter with a Variable
Speed Pump use the fastest speed.
See chaper 13 - automatic backwash
FILTER PUMP
Filtration control
7
&
8
Variable Speed Pump
1
slow
2
medium
3
fast
4
common
1000 TDS
≈
1800
μS
Attention: Use only gold redox probes!
Please see the wiring schemata in the appendix!