1. DESCRIPTION
Control panel
Cell
4 Amp fuse for panel and cell
4 Amp fuse relays
The DA-GEN is an innovative water treatment system and additional an intelligent pool controller. The DA-GEN
combines Hydrolysis with Electrolysis with a low mineral content.
The Hydrolysis produces free radicals and other oxygen compounds like ozone, peroxide and persulfate. All
these oxidants destroy organic substances and pathogens in the water. Free radicals are the strongest oxidants
we know. They oxidise and decompose in a few seconds. To guarantee a safe residual disinfection the DA-GEN
produces a very small amount of chlorine. In combination with Dryden DAISY
®
we need a very low mineral
content of 1 to 2 kg MgCl
2
or 0.75 to 1.5 kg NaCl per m
3
.
The DA-GEN also controls all your pool equipment centrally. Thanks to WiFi you can check and control your pool
system 24/7.
110-230 V
Cell
Gas detector connector
Cell connector
Cell housing
Gas detector (internal)
1
Connection cell
Gas detector connection
Main 230V connection
ON/OFF switch
USER MANUAL
2. MAIN SCREEN
PLUS
key
Modify value/selection
MINUS
key
Modify value/selection
OK
key
Select/confirm
UP key
Navigation up
DOWN key
Navigation down
RETURN/ESCAPE
key
Current time
Production intensity
in %
(normally 40-100%)
Communication display – mother board
Heating ON/OFF
Manual
Automatic
man
aut
Status of filtration relay
(see chapter 12- Filtration)
Automatic measurements:
pH/redoX/
free chlorine/conductivity
(according to options)
Lights
Manual / Automatic
man
aut
Water temperature
Polarity 1 /
Polarity 2
Filtration stopped due to lack of water flow
Waiting time
Cover
Pol 1
Flow
Low
---
Pol 2
If the cover is open the filtration speed is “medium” (if with
frequency controlled pump)
Lack of conductivity or salt / low water temperature / scale on
cell / exhausted cell
(check working hours)
7.4
7.0
ON/OFF
pH Setpoint
Setpoint pH minimum (if using pH-Minus and pH-Plus)
Function of pH dosing pump
AL3
Maximum dosing time exceeded
(
to reset the alarm)
Flow alarm (Paddle/Gas)
700
FL 1
ON/OFF
Additional chlorine pump (optional)
Minimum Redox Setpoint
AL3
Maximum dosing time exceeded
(
to reset the alarm)
Flow alarm (Paddle/Gas) / Flow alarm rotameter Cl
2
AL3
FL 1
0.30
FL 2
Free Chlorine Minimum Setpoint
Maximum dosing time exceeded
(
to reset the alarm)
Status of the auxiliary relays
TANK
Low level pH-Minus bottle
12:30
25º
man
off
man
off
Cover
Pol 1
LOW
100
%
hydrolysis
pH
7.4 OFF
AL3
7.0
7.4
Rx
mV
700 OFF
AL3
FL1
700
Cl
ppm
0.30 FL2
FL1
0.30
measures
1 2 3 4
TANK
Shortcut Backwash
(press 3s)
Shortcut Light
(press 3s)
1
Except DA-GEN 150
1
EN