WARNING: For the safety of both the operator and service personnel, care 

should be taken when using this centrifuge if handling substances that are 

known to be toxic, radioactive or contaminated with pathogenic 

microorganisms. When Risk Group II materials are used, (as identified in 

the World Health Organization “Laboratory Bio-Safety Manual”), a Bio-

Seal should be employed. The Bio-Seal accessory for the model is the non-

aerosol shield cap with appropriate tube holders (contact Drucker 

Diagnostics to purchase). In the event that materials of a higher risk group 

are being used, more than one level of protection must be provided. 

 

The use of flammable or explosive materials as well as those materials 

which have a vigorous chemical reaction is prohibited. 

 

For your safety and the durability of your machine, never transport or 

store centrifuge with tube holders inside machine. 

M

ODEL 

D

ESCRIPTION

 

The Model 614VET is a continuous-duty, electronically controlled Fixed 

Angle centrifuge with a lid safety interlock system. The unit is controlled 

by an electronic push–button timer that has been preset for two (2) 

minutes, for precise spin times and ease of use. Samples can be safely 

viewed through the transparent lid. Entry into the machine is restricted 

during operation by the safety interlock system. The Model 614VET 

features a lighted control panel that displays the status of the machine, 

easily viewable from a distance. 

I

NTENDED 

U

SE

 

General purpose laboratory centrifuge, intended for the density-based 

separation of fluids through centripetal acceleration. 

 

Users should also comply with the specimen receptable manufacturer’s 

specific instructions for use, in addition to any other protocols established 

by the testing organization. 

 

This centrifuge is intended to be used exclusively for veterinary use and 

should not be used in any non-veterinary applications. 

W

ARRANTY

 

Drucker Diagnostics warranties that this centrifuge is free from defects in 

workmanship and parts for 2 years. 

 

Summary of Contents for 614VET

Page 1: ...614VET Operator s Manual P N 03 0 0002 0229 Rev C...

Page 2: ...5 Initial Setup Procedure 6 Control Panel 7 Verifying The Preset Time 8 Changing The Preset Time 8 Operation 9 Spinning Balanced Loads 10 Rotor Removal And Installation 10 To remove the rotor 10 To i...

Page 3: ...e holders inside machine MODEL DESCRIPTION The Model 614VET is a continuous duty electronically controlled Fixed Angle centrifuge with a lid safety interlock system The unit is controlled by an electr...

Page 4: ...flow design that prevents overheating of samples Heavy gauge steel construction for safety and durability Lid safety switch that prevents the centrifuge from operating unless the lid is closed and la...

Page 5: ...uipment is present 2 Choose a setup location which meets the following criteria a A clearance height of 20 is required to open the lid b The clearance envelope is the space around the centrifuge which...

Page 6: ...the rotor and verify that they are seated properly 6 Close the lid Rotate the lid knob clockwise to its complete top position The LATCHED indicator light should be illuminated If it is not make sure...

Page 7: ...for fifteen 15 additional seconds After the centrifuge has passed this procedure it is ready for operation CONTROL PANEL RUNNING Lights up when the machine is in operation power is being applied to t...

Page 8: ...CHANGING THE PRESET TIME NOTE Your centrifuge must be plugged in a Push the OPEN STOP button to disengage the lock and then open the lid b Push and hold the START and OPEN buttons for approximately th...

Page 9: ...of two 2 minutes To display or change this time setting refer to page 8 6 Turn on the machine by pushing the START button on the control panel 7 The centrifuge should begin to spin The RUNNING indicat...

Page 10: ...plug the centrifuge from the electrical outlet to eliminate the possibility of electrical shock or other injury 2 Remove the test tube holders 3 Remove the nut in the center of the rotor by turning it...

Page 11: ...e safety guidelines of your laboratory to properly clean up and or dispose of materials in the event that a substance known to be potentially toxic radioactive or contaminated with a pathogenic microo...

Page 12: ...in water or other cleaning solutions as this will cause damage and void the warranty 3 ONLY isopropyl alcohol soap and water or a 10 5500 PPM bleach solution should be used for cleaning and disinfect...

Page 13: ...replace it if necessary The centrifuge does not run o Check the electrical outlet o Make sure the lid latch is turned completely clockwise to its stop position When the lid is closed properly the lat...

Page 14: ...t to the desired length Check the run preset by following the instructions on page 8 If the preset is not the desired length follow the procedure on the same page to change the run preset time EMERGEN...

Page 15: ...14VET has a true 0 RPM lid locking system The lid safety locking system keeps the lid locked at all times even during power failure and requires that the rotor be at rest in order to unlock the lid Th...

Page 16: ...d 7751043 Circuit Breaker 7760002 Power cord 03 1 0008 0016 Pawl latch lid 03 1 0008 0009 Knob latch lid 7724071 Hinge friction 7732018 Seal lid gasket 7713032 125mm Tube Holder Black 02 002 1 0027 Li...

Reviews: