I NS TAL L A TIO N  M A N U A L

UK

Table 2: Technical data

Product name

Type of appliance

Combustion

Supply and discharge system

Flame protection version

2nd thermocouple safety

Atmosphere safety

Explosion hatch

Ventilation hole chimney breast

Type

Type of gas

Burner pressure

Nominal Heat Input (Hs)

Nominal Heat Input (Hi)

Nominal output

Consumption

Main burner injector

Second burner injector

Overflow burner injector

Low setting injector

Burner pressure on low output*

Consumption on low output

Efficiency class

Excellence 60

Built-in

Closed combustion

Concentric 150/100

Separated ignition / ionization plugs

No

Yes

200 cm

2

C11/C31/C91

mbar

kW

kW

kW

L/h

mm

mm

mm

mm

mbar

L/h

Code

G20

14,7

10

9

7,3

933

ø1,85

ø1,5

ø0,7

A**

7,0

336

1

G25

18,7

9

8,1

6,5

960

ø1,85

ø1,5

ø0,7

A**

7,5

349

1

* Low output is measured with second burner switched off.
** A = Adjusting screw

Summary of Contents for Excellence 60

Page 1: ...E n g l i s h Store this document in a safe place Excellence 60 Installation manual UK IE DRU132368 162441 EN 0914 6 G20 G25 Natural gas UK 959 043 05 UK...

Page 2: ...chimney breast 5 7 Placing the control hatch 5 8 Flue gas discharge system appliances open combustion 5 9 Flue gas discharge combustion air supply system appliances closed combustion 5 10 Additional i...

Page 3: ...martvent system you must carefully and fully read and use the accompanying installation manual as well prior to its installation The following symbols are used in the manuals to indicate important inf...

Page 4: ...place heat resistant electrical wiring away from the appliance and as low as possible in the chimney breast This has to do with the temperature development in the chimney breast if you are installing...

Page 5: ...e of switching on manually the appliance will first return to full load Caution The appliance s control unit is characterized by its stringent safety requirements It is possible that the burning appli...

Page 6: ...connection away from the appliance as low as possible in the chimney breast This has to do with the temperature development in the chimney breast If possible place the receiver after any building wor...

Page 7: ...he control hatch see section 5 7 Proceed as follows Remove the bracket with amongst other things the gas control from the appliance by unscrewing the self tapping screws Place the bracket to which amo...

Page 8: ...chimney breast You can use DRU ventilation elements Prior to completely closing the chimney breast check whether the discharge concentric system is placed correctly whether the channels fixing bracket...

Page 9: ...rge only allowed in Great Britain the instructions provided in the separately supplied booklet Fitting into a conventional class 1 chimney apply In addition to the installation instructions this bookl...

Page 10: ...em with wall or roof terminal has to comply with the following conditions In appendix 2 table 4 or 5 you can find whether a concentric pipe should be connected and what the minimum vertical length wou...

Page 11: ...e clip binding to the pipe on locations that cannot be reached after installation Apply sufficient wall brackets so that the weight of the pipes does not rest on the appliance Determine the remaining...

Page 12: ...e glass window towards you 2 through the opening in the mounting frame and pull the top of the glass window towards you at the same time Caution Make sure you hold the handgrip firmly If you let go of...

Page 13: ...ndix 3 Fig 10 B Unscew the self tapping screws of the left and right large air inlet guide C Replace the large air inlet guides by the smaller versions see Appendix 3 Fig 11 D Tighten the small air in...

Page 14: ...sten the glow material under chips and or wood set Caution The logs should not completely cover the burner cartridge because in that case the main burner will not ignite properly which could result in...

Page 15: ...wall make sure the construction frame is level with the wall Place the mantelpiece in front of the fire see Appendix 3 Fig 30 place the lower plate E of the mantelpiece in the middle in front of the f...

Page 16: ...ormation stored in the receiver In this way the last 20 error messages can be retrieved and it will also be possible to read how many times an error occurred Moreover this remote control can also be u...

Page 17: ...ording to the instructions in the manual that is supplied with this module Now follow the steps described in the modbus protocol manual It is available from the supplier of the domotics system 6 2 2 2...

Page 18: ...t the system as described and repeat the ignition procedure until the main burner continuous to burn Caution The system can be reset and re ignited three times in a row at maximum After that the syste...

Page 19: ...f the flame picture is not acceptable in order to solve the problem 8 Maintenance Once a year the appliance should be checked cleaned and if necessary repaired by a competent installer in the field of...

Page 20: ...openers Point out the 230 Volt connection Instruct the user about the appliance and the remote control When the appliance is taken into operation point out that in order to avoid cracks in a chimney b...

Page 21: ...pin suffocating flame Ionization pin placed incorrectly Ionization pin blocked measure ionization flow when 0 and 1 8 uA Make sure the connectors of the communication cable make proper contact Replac...

Page 22: ...from burner device Burner device incorrectly mounted Pins on the connector on the gas control are bent High limit bridge defective ESYS defective burner device Window is open if this contact is presen...

Page 23: ...restrictor slide Restrictor slide Key bolts M8x140x50 Back up self tapping screws for mounting the glass panes Socket spanner 8 mm Remote control Hexagonal nut M8 Washer 8 4 mm U profile for decoratio...

Page 24: ...ominal output Consumption Main burner injector Second burner injector Overflow burner injector Low setting injector Burner pressure on low output Consumption on low output Efficiency class Excellence...

Page 25: ...length 0 51 1 4 1 4 Total number of meters horizontal pipe length excluding wall terminal 0 1 0 1 to 3 Table 4 Conditions for setting the appliance See Figure 5 5 5 Air inlet guide SMALL LARGE2 SMALL...

Page 26: ...conditions concentric system with roof terminal UK Table 5 Determining permissibility concentric system with roof terminal Total number of meters horiz pipe length Total no of meters vertical and or s...

Page 27: ...E n g l i s h INSTALLATION MANUAL UK 620 600 min 1064 max 1084 50 626 815 100 150 B B 152 360 18 606 min 163 max 183 38C 1701 2 Excellence 60 1...

Page 28: ...E n g l i s h INSTALLATION MANUAL UK min 160 610 min 350 630 min 15 max 100 min 1220 min 360 2 2 A 2 2 B 38C 1704 V Tot min 200cm A B B H D G F E A C 38C 1747 0 3 2...

Page 29: ...E n g l i s h INSTALLATION MANUAL UK 38C 1868 0 4...

Page 30: ...E n g l i s h INSTALLATION MANUAL UK 38C 1716 1 2 A B 1 0 5m 0 1m 38c 744t 1x90 1 4m 0m 38c 744q 1x90 1 4m 1 3m 38c 744s 1x90 U V T X 38C 1705 S 5x 1 2 3 38C 1718 6 5 5 7 5 8...

Page 31: ...E n g l i s h INSTALLATION MANUAL UK T Q P S 9x 38C 1709 0 R U A 38C 1706 2x C 38C 1707 2 B D 38c 1708 2 2x 12 9 10 11...

Page 32: ...E n g l i s h INSTALLATION MANUAL UK 30 40 38C 1710 38p 0229 38p 0230 38p 0022 38p 0023 38P 0028 1 16 13 14 17 18 15...

Page 33: ...E n g l i s h INSTALLATION MANUAL UK 38P 0235 G A A F E D C B 19...

Page 34: ...E n g l i s h INSTALLATION MANUAL UK 38P 0233 38P 0234 A A 38P 0236 B C 20 21 22...

Page 35: ...E n g l i s h INSTALLATION MANUAL UK 38P 0237 F E G D B 2x 8x 38C 1750 A 24 23...

Page 36: ...E n g l i s h INSTALLATION MANUAL UK I J H J L 1 2 4 3 I K 38C 1751 1 M 2x 38C 1752 1 149mm 4x A A 149 38C 1753 S C 2x 15 30mm 38C 1754 min 875 min 715 38C 1711 26 25 27 28 29...

Page 37: ...E n g l i s h INSTALLATION MANUAL UK D A 38C 1756 F E D A F G 38C 1757 G 31 30...

Page 38: ...E n g l i s h INSTALLATION MANUAL UK 38C 1871 0 Modbus WiFi Router W R D B O A 0 3 V 38p 0320 0 N L 0 3V L N N L B A C D 36 35...

Page 39: ...E n g l i s h INSTALLATION MANUAL UK 1 98 Off 1 98 Off B2 B1 B U B U C B D 38p 0318 3 P1 P2 G IN A E 38 37...

Page 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven UK...