I NS TAL LAT ION M ANUA L
!Caution
The yellow wire is the + pole, the black wire is the – pole. Always connect ‘- to -‘ and ‘+ to +’ .
6.2.2 Wireless
The wireless connection is divided into 2 types:
-
Connection via a ‘modbus’ protocol.
-
Control via an application.
!Caution
Only 1 type of wireless connection is possible on the communication module.
6.2.2.1 Connection via ‘modbus’ protocol
Wireless connection of a Domotics system to the receiver is possible via a connection according to the ‘modbus’
protocol. Such a connection can only be established with a communication module (see Appendix 3, fig. 35 (W)).
This module can be ordered from DRU. This communication module translates the ‘modbus’ protocol from the
Domotics system into a wireless signal to the receiver.
When connecting a Domotics system via the communication module to the receiver, proceed as follows:
Ø
Using the remote control, test whether the location where you want to place the communication module is within
the receiver's range.
Ø
Place the remote control on this location and test the reception sensitivity (RSSI).
Ø
Press the on/off button and down arrow at the same time. The value that is now visible, must be between -20 and
-70 (see User Manual, "Reception Sensitivity"). If needed, hold the remote control closer to the appliance in order
to improve the reception.
Ø
Connect the communication module by means of an RJ45 plug, according to the instructions in the manual that is
supplied with this module.
Ø
Now follow the steps described in the ‘modbus’ protocol manual. It is available from the supplier of the domotics
system.
6.2.2.2 Control via application
If the fire is operated via a tablet using the application (iOS or Android), a communication module is required. This
module can be ordered from DRU.
In order to control the fire via an application, proceed as follows:
Ø
Using the remote control, test whether the location where you want to place the communication module is within
the receiver's range.
Ø
Place the remote control on this location and test the reception sensitivity (RSSI).
Ø
Press the on/off button and down arrow at the same time. The value that is now visible, must be between -20 and
-70 (see User Manual, "Reception Sensitivity"). If needed, hold the remote control closer to the appliance in order
to improve the reception.
Ø
Connect the communication module by means of an RJ45 plug, according to the instructions in the manual that is
supplied with the communication module.
Ø
Use the instructions for the application in order to install it.
The application 'DRU Control' is available in the AppStore, at GooglePlay or our website: www.drufire.co.uk
7. Final inspection
In order to check whether the appliance is working properly and safely, you must perform the following
inspections before the appliance is put into operation.
7.1 Gastightness
!Caution
All connections must be gastight. Check the connections for gastightness.
The gas control may be subjected to a maximum pressure of 50 mbar.
UK
Summary of Contents for Excellence 60
Page 29: ...E n g l i s h INSTALLATION MANUAL UK 38C 1868 0 4...
Page 33: ...E n g l i s h INSTALLATION MANUAL UK 38P 0235 G A A F E D C B 19...
Page 34: ...E n g l i s h INSTALLATION MANUAL UK 38P 0233 38P 0234 A A 38P 0236 B C 20 21 22...
Page 35: ...E n g l i s h INSTALLATION MANUAL UK 38P 0237 F E G D B 2x 8x 38C 1750 A 24 23...
Page 37: ...E n g l i s h INSTALLATION MANUAL UK D A 38C 1756 F E D A F G 38C 1757 G 31 30...