English
I NS TAL LAT ION M ANUA L
Ø
Mount the bracket with components to the inner frame (A). Proceed as follows:
-
Unwind the cables. This will, amongst other things, prevent a poor operation of the ignition.
-
Unwind the flexible gas pipe(s).
-
Mount the bracket with components to the inner frame (A). The lock hole will fall into the allen screw (C);
the hole at the bottom will fall over the head of the allen screw (D).
-
Fix the bracket with allen screw (C).
!Caution
-
Avoid kinks in the pipes.
-
Do not lay the cables of the ionization pins and spark electrodes along metal parts.
Ø
Make sure there is no dirt in gas pipes and connections.
Ø
Connect the gas pipe with gas tap.
Ø
Bleed the gas pipe.
!Tip
If the gas tap is closed, you can simply remove the bracket with components by loosening the compression fitting
under the gas control and loosening the allen screw (C) a few strokes. The bracket with components can now be
lifted and removed from the control hatch in a forward movement.
Ø
Connect the 230 V mains voltage with earth connection. Various types of plug connections are supplied. The type
of plug depends on the country where the appliance is placed.
Ø
Place the data plate in its intended clamp (G).
Ø
Mount the outer frame with door (E) to the inner frame using two allen screws (D and F).
!Tip
You can place the outer frame in such a way, that the door turns to the left or to the right.
!Caution
Always close the control hatch with the lock (H) because of the electricity behind the door (230V).
You can operate the lock with a fitting flat object.
5.8 Flue gas discharge system at appliances with an open combustion (type B11)
For connection to an existing chimney without a discharge pipe or flexble SS discharge – only allowed in Great
Britain – the instructions provided in the separately supplied booklet 'Fitting into a conventional class 1 chimney'
apply. In addition to the installation instructions, this booklet also contains supplementary tests.
5.8.1 General
The appliance's type of discharge system is stated in Appendix 2, Table 2.
The appliance must be connected to an existing or newly to be built chimney, according to the applicable,
national, local and constructional (installation) regulations.
5.8.2 Connection of flue gas discharge system
(if a class 1 chimney is not applicable)
At least a 3 metre discharge pipe or a flexible SS discharge should be connected to the appliance.
Bends in the flue gas discharge system are not allowed.
!Caution
-
Maintain a distance of at least 50 mm between the outside of the concentric system and the walls and/or
ceiling. If the system is built in (for instance) a cove, it should be made with non combustible material all
around it;
-
Use heat-resistant insulation material when passing through combustible material;
-
Use a flue gas discharge system with the correct diameter, and which is provided with the CE mark;
!Caution
Some heat-resistant insulation materials contain volatile components that will spread an unpleasant smell for a
prolonged time; these are not suitable.
Place the flue gas discharge system as follows:
Ø
Connect the pipe pieces or flexible SS discharge.
Ø
You should only install the appliance in a well ventilated room which complies with the applicable national, local
and constructional (installation) regulations, in order to guarantee sufficient air supply.
!Caution
-
In case of a house with a mechanic exhaust system and/or an open kitchen with cooker hood, a permanent
ventilation hole is required in the area surrounding the appliance; for this application, please refer to the gas
installation regulations and local legislation.
UK
Summary of Contents for Excellence 60
Page 29: ...E n g l i s h INSTALLATION MANUAL UK 38C 1868 0 4...
Page 33: ...E n g l i s h INSTALLATION MANUAL UK 38P 0235 G A A F E D C B 19...
Page 34: ...E n g l i s h INSTALLATION MANUAL UK 38P 0233 38P 0234 A A 38P 0236 B C 20 21 22...
Page 35: ...E n g l i s h INSTALLATION MANUAL UK 38P 0237 F E G D B 2x 8x 38C 1750 A 24 23...
Page 37: ...E n g l i s h INSTALLATION MANUAL UK D A 38C 1756 F E D A F G 38C 1757 G 31 30...