SECTION 5
YOUR ARMOR X7 SOFTWARE
PAGE 119
9711-26400-0001
EXPORT CONTROLLED – SEE PAGE 3
Rev A
C harge B oth
If you select
Charge Both
, both batteries will charge at the same time regardless of individual
battery charge level. The total charge level indicated is determined by adding the charge of both
batteries and dividing this sum by 2.
C harge L owes t F irs t
If you choose
Charge Lowest First
, the battery with the lowest charge will be charged to 80%,
followed by the next lowest battery. Once both are at 80%, the first charged battery will be
charged to 100%, followed by the second charged battery.
Click on
OK
to save the new default setting. Select
CANCEL
to exit without changing the policy.
C onditioning Menu B utton
Click on the
Conditioning Menu
button to open the Battery Conditioning window shown in
Figure 62. This window will display the conditioning cycle information for each battery. It also
allows you to select a single battery to condition, or to select both batteries.
Your X7 batteries are self conditioning/calibrating and do not normally require conditioning.
NOTE
Conditioning, or calibration, should only be performed if you notice
that the levels reported by Windows or ARMORutils are
consistently different from actual battery performance, as this adds
to the total cycle count of the battery.
The conditioning process consists of first charging the battery to a full charge, then drawing the
charge down to its minimum, followed by charging the battery back to a full charge.
NOTE:
A
negative value may appear for the discharge cycle mAh reading; this is normal.
The entire conditioning process takes about 8 hours for two batteries.