18/22
9.2 PARAMETERS AND VALUES
The following table shows the parameters and possible values of VIP5 Plus. The first two parameters (MODE and
TYPE) determine what parameters are available in the menu and they are the first that must be set.
PARAMETER
NAME
DEFAULT
VALUE
DESCRIPTION
VALUES/ RANGE
APPLICABILITY
MODE
CYCLE
SELECT THE OPERATIMG MODE:
Flow monitoring mode
FLOW
FLO
W
Lubrication Cycle completed when the cycle sensor
confirms correct lubrication
CYCLE
CY
CL
E
Both Standby and Lubrication Phase determined by
external signal.
PULSE
PU
LSE
TYPE
SEP
SELECTS THE CYCLE MONITORING:
X
X
Timer only
TIMER
Pressure switch
PS
TIM
ER
/N
O
CO
N
TR
O
L
Progressive Cycle switch
SEP
PS
Dual Line cycle with control signals
DUAL
DU
AL
SE
P
Timed Dual Line cycle
DUAL TIMED
D
U
AL
TIM
ED
INVERTER
PNEUM
Type of connected inverter for Dual systems
PNEUM-ELETT
X
X
X
INVER.Ton
3s
Time for inversion
0,1s - 25,0s
X
X
X
X
INVE.Wait
.null.
Waiting time for inversion command and pump
1s - 1h
X
X
X
X
CYCLE TOUT
2 min
Timeout counter determines how long to wait for cycle
completion before a timeout alarm is generated
1s - 1h
X
X
X
X
X
X
LUBE TIME
2 min
In timer Mode, how long the pump will run
0s – 99h
X
X
CYCLE CNT
1
The Duration of the Lubrication cycle (in PULSE Mode)
1 - 60000
X
X
X
X
X
X
DELAY TIM
5s
When the pressure switch is made, how long to keep the
pump running to ensure that the signal is genuine and not a
pressure spike
0s – 2min
X
X
X
X
X
With FLOW mode time that alarm condition must exist
before being reported
X
SUSPEND T
1s
In Pulse Mode, will suspend the Lubrication Phase if a signal
is not received
Null – 2min
X
X
X
X
X
X
PAUSE CNT
1
Counter for standby phase (PULSE input).
See: PAUSE MULTIP.
Null -250
(cycle mode)
Null-60000
(pulse mode)
X
X
X
X
X
X
X
SUSPEND
Never
With cycle mode suspend remote signal on pulse input can
be connected. The lubrication cycle is completed before
any suspension
Never, In Pause
In Cycle, Always
X
X
X
X
X
X
PAUSE BY
Timer
Determines Standby Phase Timing
X
X
X
X
X
X
Time based Standby
Time
A set number of external PULSE signals
Counter
Whichever of above 2 events occurs first
Time & Counter
By PULSE signals. However, if PAUSE TIM. is reached, an
alarm will be given
Tout
& Count
PAUSE TIM.
6m 00s
Standby Timer setting. Null means the standby phase will
be skipped
Null
– 99h 00m
X
X
X
X
X
X
PUMP
Continuous
Pump output can be constant signal, pulsed signal or
synchronized with control signal (see next 3 parameters)
Continuous,
Pulsed
X
X
X
X
X
X
X
syncronyzed
X
PUMP TON
5,0
Sets the ON value of the pump pulse
0,1-25,0s
X
X
X
X
X
X
X
PUMP TOFF
5,0
Sets the OFF value of the pump pulse
0,1-25,0s
X
X
X
X
X
X
X
PAUSE MULTIP.
1
Multiply pause settings by 10 or 100 to achive more higt
values. See: PAUSE CNT
1; 10; 100
X
X
X
X
X
X
LUBE CYCLES
1
Number of Lubrication Cycles to complete a Lubrication
Phase
1 - 250
X
X
X
X
X
X
BOOST CYCLES
1
In a SEP mode, If P2 input is closed the LUBE CYCLES values
is increased by this value contained in this setting
1 - 250
X
X