DROPSA MiQueL EXT User Operating And Maintenance Manual Download Page 8

 

10. DISPOSAL

 

 
During machine maintenance, or if it is demolished, do not dispose of the polluting parts in an improper manner. Refer to the 
local  regulations  for  their  correct  disposal.  When  demolishing  the  machine,  the  identification  plate  and  all  other  documents 
must be destroyed. 

 

11.  

ORDER INFORMATION 

 

VERSION 

DESCRIPTION 

CODE 

MiQueL PRO 

Air/Oil modular minimal system 

with

 compensation valve  

without

 a solenoid valve for independent control 

N

(1-8) modules 

313558

N=

1÷8 (Modules) 

MiQueL PRO 

i

 

Air/Oil modular minimal system 

with

 compensation valve  

with

 a solenoid valve for independent control 

N

(1-8) modules 

313559

N=

1÷8 (Modules) 

MiQueL BASE 

Air/Oil modular minimal system 

without

 compensation valve  

without

 a solenoid valve for independent control 

N

(1-8) modules 

313560

N=

1÷8 (Modules) 

MiQueL BASE 

i

 

Air/Oil modular minimal system 

without

 compensation valve  

with

 a solenoid valve for independent control 

N

(1-8) modules 

313561

N=

1÷8 (Modules) 

 

11.1 ACCESSORIES AND SPARE PARTS 

ACCESSORIES AND SPARE PARTS 

CODE 

DESCRIPTION 

CODICE 

DESCRIPTION 

1525430  MiQueL PRO- 

i

 - Modular element 

5717301 

Ø6 AIR outlet pipe 

1525440  MiQueL PRO - Modular element 

3226664 

Oil MK 150 20 lt. 

1525450  MiQueL BASE

i

 - Modular element 

3226665 

Oil MK 100 25 lt. 

1525460  MiQueL BASE - Modular element 

3226666 

Oil MK High Performance 29 lt. 

3133561  Pressurized Reservoir for  MiQueL EXT – 1lt 

3225465 

Oil MK Stainless 20 lt 

3133560  Pressurized Reservoir for  MiQueL EXT – 3lt 

3133455 

Coaxial nozzle - Narrow Cone Pattern 

0020694  Pressure gauge for module AIR outlet (

-

i

 

3133558 

65° Coaxial nozzle – flat cone 

1525446  Module solenoid valve connector (

-

i

)with 600mm cable 

3133564 

FULL cone monotube nozzle 

1525476  Module solenoid valve connector (

-

i

)with M8 connector 

3133565 

65° monotube nozzle flat cone 

1525442  Module solenoid valve (

-

i

1525050 

Monotube nozzle for 50mm BLADE 

5717232  Outlet oil  Ø3 tube 

1525051 

Monotube nozzle for 70mm BLADE 

 
For more information about accessories and spare parts, contact our technical sales office. 

 

Summary of Contents for MiQueL EXT

Page 1: ...4 TECHNICAL FEATURES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLI...

Page 2: ...anaged independently between the different modules using a mini solenoid valve i version only that activates the control valves on the module The module has a compensation valve PRO version only is ab...

Page 3: ...lation with air inlet pressure Air inlet pressure 4bar 7bar 87psi 101 5psi Maximum air consumption at the outlet 50Nl min per module Air inlet pipe 6mm Oil inlet pipe 6mm Air outlet pipe 6mm Oil outle...

Page 4: ...y system increasing modular elements Final closure screws Modular element Screw assembly modules Fixing intermidia set screw Starting element End cover Modular element outlets Air inlet Mounting screw...

Page 5: ...s specified in the safety sheet for the lubricant Do not use aggressive lubricants with NBR gaskets In the case of doubt contact the Dropsa SpA technical office to receive a detailed card about the re...

Page 6: ...air outlet push in Then connect the same coaxial pipes to the lubrication nozzle push in as shown below 1 Insert the 6 air pipe in the push in on the nozzle connection 2 Remove the nozzle head from t...

Page 7: ...the problem after consulting the diagnostics table do not try to find the fault by disassembling machine parts but contact the Dropsa technical office and report the discovered anomalies with a detai...

Page 8: ...ependent control N 1 8 modules 313561N N 1 8 Modules 11 1 ACCESSORIES AND SPARE PARTS ACCESSORIES AND SPARE PARTS CODE DESCRIPTION CODICE DESCRIPTION 1525430 MiQueL PRO i Modular element 5717301 6 AIR...

Page 9: ...9 12 DIMENSIONS MiQueL EXT Reservoir for MiQueL EXT optional Dimensions in mm inch...

Page 10: ...tructures must be connected to the ground line Inflammability The lubricant used in the lubrication circuits is normally not an inflammable liquid It is however necessary to adopt all the possible mea...

Page 11: ...le for this purpose suitable PPE must be worn during maintenance activities Unsuitable postures The correct dimensions and installation methods are described in this manual Use of unsuitable lubricant...

Page 12: ...of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such ne...

Page 13: ...siones Vers es EXT PRO EXT PRO I EXT BASE EXT BASE I Codici Codes C digos 3135581 3135618 conforme alle condizioni previste dalle Direttive CEE has been constructed in conformity with the Directives O...

Page 14: ...k dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Reviews: