DROPSA MiQueL EXT User Operating And Maintenance Manual Download Page 2

 

1. INTRODUCTION 

 
This user and maintenance manual relates to the 

MiQueL EXT

.  

Using this pump means that oils and greases can be distributed within lubrication systems even at high pressures of up to 400 
bar (5880 psi).  
The  latest  version  may  be  obtained  from  the  Technical-Commercial  Office,  or  by  consulting  our  web  site 
http://www.dropsa.com. 
The pump subject of this manual must be used by qualified personnel with basic hydraulic and electrical knowledge. 
This user and maintenance manual contains important information about protecting the health and safety of the personnel who 
intend  to  use  this  apparatus.  You  must  read  and  look  after  it  carefully,  making  sure  that  it  is  available  at  all  times  for  the 
operators who intend to consult it. 
 

2. GENERAL DESCRIPTION 

Operation 

The  system  consists  of  a  pressurised  lubricant  tank,  one  or  more  mixture  regulation  modules,  pipes  and  spray  nozzles  (see 
hydraulic diagram below). 
The lubricant is sent to mixing valve 

 through an external pump or a pressurised reservoir. 

Each module has oil 

 and air 

 check valves that are controlled manually by the operator. The outward oil and air flow can 

be managed independently between the different modules using a mini solenoid valve 

 (

“-

i

”version only) that activates the 

control valves 

 on the module. The module has a compensation valve 

 (

“PRO”

 version only) is able to keep the flow rate 

constant as the inlet tank pressure and outlet counter-pressure varies. 
The  lubrication  pipes  can  be  traditional  or  coaxial.  In  the  latter  case,  the  lubricant  and  nebulisation  air  are  transported 
separately to the nozzle. The piston 

 keeps the oil from dripping from the nozzle when the lubrication operation is complete. 

 

Hydraulic diagram 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
Spray nozzles 

When traditional pipes are used, the air and oil are already mixed when they arrive at the nozzle. 
If coaxial pipes are used, the nozzle mixes the air and oil at the point to be lubricated. The lubricant is atomised in minuscule 
particles by the air flow that passes in front of the oil outlet hole.  
The geometry of the nozzle is designed based on the type of spray to be obtained (conic, blade-shaped, etc.). 

 

Advantages 

 

Easy to install on the machine 

 

Reduction in tool wear 

 

Improved surface finish on the part 

 

No lubricant residuals left on the part when the work is complete 

 

The nozzles do not drip after being turned off 

 

Large spray range (up to 300 mm) 

 

Greater safety and environmental hygiene at the workplace 

 
 
 
 

Serbatoio pressurizzato 

(Optional) 

Summary of Contents for MiQueL EXT

Page 1: ...4 TECHNICAL FEATURES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLI...

Page 2: ...anaged independently between the different modules using a mini solenoid valve i version only that activates the control valves on the module The module has a compensation valve PRO version only is ab...

Page 3: ...lation with air inlet pressure Air inlet pressure 4bar 7bar 87psi 101 5psi Maximum air consumption at the outlet 50Nl min per module Air inlet pipe 6mm Oil inlet pipe 6mm Air outlet pipe 6mm Oil outle...

Page 4: ...y system increasing modular elements Final closure screws Modular element Screw assembly modules Fixing intermidia set screw Starting element End cover Modular element outlets Air inlet Mounting screw...

Page 5: ...s specified in the safety sheet for the lubricant Do not use aggressive lubricants with NBR gaskets In the case of doubt contact the Dropsa SpA technical office to receive a detailed card about the re...

Page 6: ...air outlet push in Then connect the same coaxial pipes to the lubrication nozzle push in as shown below 1 Insert the 6 air pipe in the push in on the nozzle connection 2 Remove the nozzle head from t...

Page 7: ...the problem after consulting the diagnostics table do not try to find the fault by disassembling machine parts but contact the Dropsa technical office and report the discovered anomalies with a detai...

Page 8: ...ependent control N 1 8 modules 313561N N 1 8 Modules 11 1 ACCESSORIES AND SPARE PARTS ACCESSORIES AND SPARE PARTS CODE DESCRIPTION CODICE DESCRIPTION 1525430 MiQueL PRO i Modular element 5717301 6 AIR...

Page 9: ...9 12 DIMENSIONS MiQueL EXT Reservoir for MiQueL EXT optional Dimensions in mm inch...

Page 10: ...tructures must be connected to the ground line Inflammability The lubricant used in the lubrication circuits is normally not an inflammable liquid It is however necessary to adopt all the possible mea...

Page 11: ...le for this purpose suitable PPE must be worn during maintenance activities Unsuitable postures The correct dimensions and installation methods are described in this manual Use of unsuitable lubricant...

Page 12: ...of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such ne...

Page 13: ...siones Vers es EXT PRO EXT PRO I EXT BASE EXT BASE I Codici Codes C digos 3135581 3135618 conforme alle condizioni previste dalle Direttive CEE has been constructed in conformity with the Directives O...

Page 14: ...k dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Reviews: