DROPSA MiQueL EXT User Operating And Maintenance Manual Download Page 7

 

7. INSTRUCTIONS FOR USE 

 

Operations to perform before start-up. 

 

Check the integrity of the unit. 

 

Check the power supply pressure. 

 

Check that the electric connection was carried out correctly. 

 

Check that the unit is at the operating temperature. 

 

7.1 USE 

 

Open the manual cursor valve; 

 

Press the start button on the machine to which the unit is connected or start it; 

 

Check that the solenoid valves on the elements are correctly activated; 

 

At the first start-up, it may be necessary to fill the oil pipes, wait until the lubricant exits; 

 

Check that the lubrication is suitable (if there are doubts about correct operation, the Dropsa SpA technical office can be 
contacted to request the inspection procedure). 

 

7.2 REGULATION 

The modular elements are normally supplied with the oil regulation and the air regulation completely closed. To regulate the 
air/oil mixture for the individual elements, proceed as follows: 

 

Turn the oil regulation knob clockwise to increase the flow rate or anticlockwise to decrease the flow rate. 

 

Use a screwdriver to turn the air regulation pin clockwise to increase the flow rate or anticlockwise to decrease the flow rate, 
until the desired spray is obtained. 

 
8. PROBLEMS AND SOLUTIONS 

 

 

 
A diagnostics table is provided below that indicates the main anomalies, the probable causes and the possible solutions. 
If you were not able to solve the problem after consulting the diagnostics table, do not try to find the fault by disassembling 
machine parts but contact the Dropsa technical office and report the discovered anomalies, with a detailed description. 

 

DIAGNOSTICS TABLE 

ANOMALY 

CAUSE 

SOLUTION 

Lubrication does not take place 
activating the solenoid valve. 

Solenoid valve broken. 

Replace the solenoid valve. 

The air supply pressure is below 4 bar

 

[58psi]

Increase the supply pressure up to a 
minimum of 4 bar. 

The lubricant exits irregularly and with 
large air bubbles visible in the Ø3 oil 
pipe. 

The Ø3 oil pipe is not perfectly engaged 
into push-in of module. 

Top up the tank with new lubricant. 
Insert the pipe, making sure to insert it to 
the end. 

 

 

 
 
9. MAINTENANCE PROCEDURES 

 
The units were designed and built in order to minimise maintenance requirements. 
To simplify maintenance, it is recommended to install them in an easy to reach position.  
(See paragraph 6.2). 

 

Periodically check the pipe joints to detect any leaks. 

 

Always keep the modules clean to be able to quickly detect any leaks. 

The  machine does  not  require  any  special equipment  for  any  control  and/or  maintenance activity.  It  is  recommended  to  use 
tools and personal protective devices suitable for use in ref. to leg. Decree 81/2008, and that are in good condition according to 
current regulations to prevent damage to people or machine parts. 

 

 

 
 

ATTENTION: Make sure that the pneumatic power supply is disconnected before carrying out any maintenance 
work.

 

 

 

ATTENTION: The unit may only be opened and repaired by authorised Dropsa personnel. 

  

 

Summary of Contents for MiQueL EXT

Page 1: ...4 TECHNICAL FEATURES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLI...

Page 2: ...anaged independently between the different modules using a mini solenoid valve i version only that activates the control valves on the module The module has a compensation valve PRO version only is ab...

Page 3: ...lation with air inlet pressure Air inlet pressure 4bar 7bar 87psi 101 5psi Maximum air consumption at the outlet 50Nl min per module Air inlet pipe 6mm Oil inlet pipe 6mm Air outlet pipe 6mm Oil outle...

Page 4: ...y system increasing modular elements Final closure screws Modular element Screw assembly modules Fixing intermidia set screw Starting element End cover Modular element outlets Air inlet Mounting screw...

Page 5: ...s specified in the safety sheet for the lubricant Do not use aggressive lubricants with NBR gaskets In the case of doubt contact the Dropsa SpA technical office to receive a detailed card about the re...

Page 6: ...air outlet push in Then connect the same coaxial pipes to the lubrication nozzle push in as shown below 1 Insert the 6 air pipe in the push in on the nozzle connection 2 Remove the nozzle head from t...

Page 7: ...the problem after consulting the diagnostics table do not try to find the fault by disassembling machine parts but contact the Dropsa technical office and report the discovered anomalies with a detai...

Page 8: ...ependent control N 1 8 modules 313561N N 1 8 Modules 11 1 ACCESSORIES AND SPARE PARTS ACCESSORIES AND SPARE PARTS CODE DESCRIPTION CODICE DESCRIPTION 1525430 MiQueL PRO i Modular element 5717301 6 AIR...

Page 9: ...9 12 DIMENSIONS MiQueL EXT Reservoir for MiQueL EXT optional Dimensions in mm inch...

Page 10: ...tructures must be connected to the ground line Inflammability The lubricant used in the lubrication circuits is normally not an inflammable liquid It is however necessary to adopt all the possible mea...

Page 11: ...le for this purpose suitable PPE must be worn during maintenance activities Unsuitable postures The correct dimensions and installation methods are described in this manual Use of unsuitable lubricant...

Page 12: ...of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such ne...

Page 13: ...siones Vers es EXT PRO EXT PRO I EXT BASE EXT BASE I Codici Codes C digos 3135581 3135618 conforme alle condizioni previste dalle Direttive CEE has been constructed in conformity with the Directives O...

Page 14: ...k dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Reviews: