background image

 

 

 

MiQueL EXT 

Air/oil modular minimal system 
With external pump 

 

User Operating and 
Maintenance Manual 

 

 

Original text translation  

 

Warranty Information 

 

 
 
 
 
 

CONTENT 
 
  1.  

INTRODUCTION 

  2.  

GENERAL DESCRIPTION 

  3. 

IDENTIFICATION OF THE MACHINE 

  4.  

TECHNICAL FEATURES  

  5.  

MACHINE COMPONENTS  

  6.  

UNPACKING AND INSTALLATION  

  7.  

INSTRUCTIONS FOR USE  

  8.  

PROBLEMS AND SOLUTIONS  

  9.  

MAINTENANCE PROCEDURES  

10.  

DISPOSAL  

11.  

ORDER INFORMATION  

12.  

DIMENSIONS  

13.  

HANDLING AND TRANSPORT  

14.  

PRECAUTIONS FOR USE  

15.  

OPERATIONAL HAZARDS

  

 

16.  

WARRANTY  

17.  

DECLARATION OF COMPLIANCE  

18.  

DISTRIBUTORS 

 
 
 
 
 
 
 
 
 

 
 
The manual has been prepared in compliance with Directive                          C2168IE – WK 01/12 
EC 06/42

 

 

http://www.dropsa.com 

Summary of Contents for MiQueL EXT

Page 1: ...4 TECHNICAL FEATURES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLI...

Page 2: ...anaged independently between the different modules using a mini solenoid valve i version only that activates the control valves on the module The module has a compensation valve PRO version only is ab...

Page 3: ...lation with air inlet pressure Air inlet pressure 4bar 7bar 87psi 101 5psi Maximum air consumption at the outlet 50Nl min per module Air inlet pipe 6mm Oil inlet pipe 6mm Air outlet pipe 6mm Oil outle...

Page 4: ...y system increasing modular elements Final closure screws Modular element Screw assembly modules Fixing intermidia set screw Starting element End cover Modular element outlets Air inlet Mounting screw...

Page 5: ...s specified in the safety sheet for the lubricant Do not use aggressive lubricants with NBR gaskets In the case of doubt contact the Dropsa SpA technical office to receive a detailed card about the re...

Page 6: ...air outlet push in Then connect the same coaxial pipes to the lubrication nozzle push in as shown below 1 Insert the 6 air pipe in the push in on the nozzle connection 2 Remove the nozzle head from t...

Page 7: ...the problem after consulting the diagnostics table do not try to find the fault by disassembling machine parts but contact the Dropsa technical office and report the discovered anomalies with a detai...

Page 8: ...ependent control N 1 8 modules 313561N N 1 8 Modules 11 1 ACCESSORIES AND SPARE PARTS ACCESSORIES AND SPARE PARTS CODE DESCRIPTION CODICE DESCRIPTION 1525430 MiQueL PRO i Modular element 5717301 6 AIR...

Page 9: ...9 12 DIMENSIONS MiQueL EXT Reservoir for MiQueL EXT optional Dimensions in mm inch...

Page 10: ...tructures must be connected to the ground line Inflammability The lubricant used in the lubrication circuits is normally not an inflammable liquid It is however necessary to adopt all the possible mea...

Page 11: ...le for this purpose suitable PPE must be worn during maintenance activities Unsuitable postures The correct dimensions and installation methods are described in this manual Use of unsuitable lubricant...

Page 12: ...of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such ne...

Page 13: ...siones Vers es EXT PRO EXT PRO I EXT BASE EXT BASE I Codici Codes C digos 3135581 3135618 conforme alle condizioni previste dalle Direttive CEE has been constructed in conformity with the Directives O...

Page 14: ...k dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling...

Reviews: