background image

C20008IE – Pneumatically driven pump  -  Rev. 0                February 99                 Page 5 of 9                  

 

 

+

     action to be taken prior to start up 

 

Verify the integrity of the pump; 
Fill the tank with suitable lubricant (min/max indication on the tank); 

Verify that the pump is at operating temperature and the tubing free from air bubbles; 

Check that the electrical connections have been effected correctly (CEI 64/8, IEC 364); 
Verify the correct connections of any level and pressure switches to the control panel 

 

 

3.2 

Use 

 

1. 

verify the settings on the control panel, where fitted; 

2. 

press the start button of the machine to which the pump is connected; 

3. 

verify the starting of the pump;  

4. 

verify the adequate lubrication of the machine (if doubt exists as to the correct functioning consult the 
Engineering Department of Dropsa SpA to request test procedures). 

 

3.3 

Transport and storage 

 
Transport and storage is effected in a cardboard package. 
No particular precautions are required except as noted on the package itself. 
Handling can be effected by one person. 

 

!

  

Lift the unit with taking account of the right way up indicated on the cardboard carton 

!

     

The machine components can withstand temperatures, during storage, from -20 to +50°C; however, in 
order to avoid damage, starting of the machine should occur at a minimum temperature of -5°C.. 

 

3.4 

Assembly/Disassembly 

 
No pump assembly operations are envisaged. 
For wall or floor mounting ensure adequate space is available (as shown in the installation diagram) to avoid 
abnormal postures and possible impacts; four fixing holes are provided with different characteristics depending on 
the version (see section 2.2) 
Subsequently it will be necessary, as previously described, to connect the pump to the machine hydraulically and 
then to connect the control panel. 
 
 
During the disassembly phase ensure the tank is empty. 
Disconnect the electrical, hydraulic and pneumatic parts. 

Where the machine is to be scrapped, do not dispose of potentially polluting parts in the environment, 
following local regulations for their correct disposal. 

At the time of the machine being scrapped it is necessary to remove and destroy the identification plate and all 
other relative documents. 
 

3.5 

Regulation 

 
The only parameter which can be modified is the pressure; to modify the value increase or decrease the pressure of 
the command air/hydraulic supply. 
 

3.6 

Maintenance 

 

!

  

 Locate the machine in conditions which facilitate easy access. 

 

Utilise individual protection to avoid contact with mineral oil or grease. 

 

Having undergone rigorous testing by ourselves, the pump does not require any further maintenance. The use of 
lubricants free from impurities is recommended and the periodic careful cleaning of the component parts of the 
pump. 

Summary of Contents for 3103014

Page 1: ...WARNING 1 0 DESCRIPTION OF THE PUMP 2 0 TECHNICAL SPECIFICATIONS 3 0 CORRECT USE 4 0 INSTRUCTIONS FOR ORDERING AND DISTRIBUTORS DECLARATION OF CONFORMITY Catalogue P N C2008IE Wk 05 99 Registered nam...

Page 2: ...ubject the pump the tubing or other parts under pressure to violent impacts damaged tubing or connections are dangerous and should be replaced After prolonged periods of inactivity ensure the tightnes...

Page 3: ...ECIFICATIONS 2 1 Methods of commanding the pump Manual push button control 3 way solenoid valve control Mechanical roller or cam bar control Supply Supply Supply Discharge Discharge Discharge C20008IE...

Page 4: ...this purpose beforehand by the supplier For correct fixing verify the distance between centres shown in the diagram in Section 2 2 Use gloves and safety glasses as required in the lubrication oil safe...

Page 5: ...r at a minimum temperature of 5 C 3 4 Assembly Disassembly No pump assembly operations are envisaged For wall or floor mounting ensure adequate space is available as shown in the installation diagram...

Page 6: ...mbly The following should be checked periodically VERIFY WORK CYCLES The state of lubrication 100 The oil level 200 The cleanliness of the suction filter 400 The cleanliness of the loading return filt...

Page 7: ...Machine Directive is effected by means of the compilation of a check list which has been pre prepared and is contained in the technical file The lists which are utilised are of three types list of dan...

Page 8: ...NLGI1 30 1 5 0 5 2 YES 3413014 Pneum S A NLGI1 30 1 10 0 5 2 NO 3413016 Pneum S A NLGI1 30 1 5 0 5 2 YES with loading filter 3413018 Pneum S A NLGI1 30 1 3 0 5 2 YES 3413019 Pneum S A NLGI3 30 1 10 0...

Page 9: ...RECTIVE OF THE COUNCIL OF THE EUROPEAN COMMUNITY concerning the harmonisation of member states legislation relative to machines 89 392 CEE 91 368 CEE EMC 89 336 CEE and BT 73 23 CEE and relative amend...

Page 10: ......

Page 11: ......

Reviews: