13. HANDLING AND TRANSPORT 

 

Prior to shipping, the equipment is carefully packed in cardboard package. During transportation and storage, always maintain 

the pump the right way up as indicated on the box. On receipt check that package has not been damaged. Then, storage the 

machine in a dry location. 

 

 

 

 

 

 

 

14. PRECAUTIONS FOR USE 

 

 

 

 

 

 

14.1 HYDRAULIC SUPPLY 

Any type of intervention must not be carried out before the unplugging of the machine from hydraulic supply.  

14.2 FLAMMABILITY 

The lubricant generally used in lubrication systems is not normally flammable.  
However, it is advised to avoid contact with extremely hot substances or naked flames.  

14.3 PRESSURE 

Prior to any intervention, check the absence of residual pressure in any branch of the lubricant circuit as it may cause oil sprays 
when disassembling components or fittings.  

14.4 Noise 

The pump does not produce excessive noise (less than 70 dB(A) ) at the distance of 1 m (39.3 inches) from the pump. 

 

LUBRICANTS 

 

 

 

 

 

 

The following is a comparison table between NLGI (National Lubricating Grease Institute) and ASTM (American Society for 

Testing and Materials) for greases, showing the permissible values for the Hyd-min PUMP  

 

GREASES 

NLGI 

ASTM 

000 

445 – 475 

00 

400 – 430 

355 – 385 

310 – 340 

265 –295 

 

For more information on technical and security measures, see the Security tab of the Product (Directive 93/112/EEC) relating to 

the type of lubricant chosen and supplied by the manufacturer. 

 

Lift the packaging taking note of the orientation of the pump. 

The product can withstand a storage temperature between -20 to + 50 °C; however it is necessary to ensure that the 

product has stabilized at a minimum temperature of +5 °C before putting it into operation

 

 

NOTE: 

The pump has been designed to work with greases with a maximum viscosity of NLGI 2 

Always use lubricants that are compatible with NBR Rubber. 

The lubricant used during final testing of the unit is a NLGI 2 grease

.

 

 

WARNING:

 It’s necessary read carefully the warnings about the risks involving the use of a pump for lubricants. 

The user must know the operation through the User Manual and Maintenance.

 

 

 

Summary of Contents for 0234560

Page 1: ...NS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT 14 PRECAUTIONS FOR USE 15 OPERATIONAL HAZARDS Manual compiled in a...

Page 2: ...ations Manufactured in high quality carbon steel the pump design features allow it to work with viscous lubricants without any additional complicated priming procedures The pump when combined with a s...

Page 3: ...duct for your application 4 TECHNICAL FEATURES GENERAL CHARACTERISTICS Pumping System Hydraulically activated Piston mechanism Lubricant Outlet Port 3 8 BSP UNI ISO 228 1 Return Line Port 1 4 BSP UNI...

Page 4: ...tant to inspect the pump to ensure that there has been no damage during transportation The packaging material used does not require any special disposal procedures You should refer to you regional req...

Page 5: ...l Inverter the electrically controlled valve switches the flow of oil from P A to P B and vice versa The user must not use a operating frequency less than 0 5 sec per change over Always ensure the int...

Page 6: ...substances and should be disposed of following local regulations including any recycling information indicated on the components themselves Upon demolition of the machine you must destroy the identifi...

Page 7: ...1141607 FOLLOWER PLATE 25KG D 320 1141602 FOLLOWER PLATE 50KG D375 1141604 FOLLOWER PLATE 200KG D580 3005141 LOCK RING 0234570 HYD INVERT AUTOMATIC CETOP 3 0234571 ELE INVERT 24VDC CETOP 3 0234572 EL...

Page 8: ...8 12 DIMENSIONS Dimensions in mm in...

Page 9: ...p LUBRICANTS The following is a comparison table between NLGI National Lubricating Grease Institute and ASTM American Society for Testing and Materials for greases showing the permissible values for t...

Page 10: ...g appropriate personal protective clothing and glasses Electrocution This can occur if the user does not securely connected the wires inside the terminal box Electrical connections must therefore be c...