background image

 

The follower plate: 

It is necessary  to use a follower plate to correctly pump heavy grease (e.g.  NLGI 2).  The plate is 

manufactured in 10mm/0.39” thick steel and has a lip seal around the edge and an O Seal along the central shaft to avoid grease 

leak-through. The follower plate: 

-

 

Compresses grease thereby avoiding air pockets; 

-

 

Allows effective emptying of the barrel by wiping grease from the side of the barrel that would otherwise go to waste. 

 

The Barrel Cover 

reduces the possible contamination of the grease in the barrel. It is supplied with retaining screws and also has the 

purpose of holding the pump in a correct vertical configuration.  

 

 

3. IDENTIFICATION OF THE MACHINE 

 

On the pump cover there is a product identification label that indicates the part number and characteristic of the pump. Always 

ensure you have the correct product for your application. 

 
 

4. TECHNICAL FEATURES 

 

 

 

 

 

 

 

 

 

GENERAL CHARACTERISTICS 

Pumping System 

Hydraulically activated Piston mechanism 

Lubricant Outlet Port  

 3/8” BSP  ( UNI ISO 228/1 ) 

Return Line Port 

 1/4” BSP  (UNI ISO 228/1 ) 

Hydraulic Feed/Return Port Connection (A – B) 

3/8” BSP   (UNI ISO 228/1) 

Cover Plate Pump stem passage (removable)

   

 

Rc 2”   (UNI-ISO 7/1) 

Maximum working pressure 

400bar - 5800 PSI 

By Pass pressure  

Adjustable  80 bar ÷ 450 bar (1160 psi ÷ 6526 psi) 

Usable Grease Index Range 

NLGI 000 – NLGI 2 

Nominal Output per Pump Stroke 

5cc/stroke  

Minimum Hydraulic input pressure 

30bar – 400 PSI 

Oil flow requirment per stroke 

83.5 cc 

Pump Pressure Ratio  

10:1 

Maximum operating frequency 

100 strokes per minute  

Hydraulic fluid cleanliness requirement 

ISO 4406:1999 class 20/18/15 

Hydraulic circuit olio viscosity range   

10cSt ÷ 400cSt 

Storage Temperature  

-30°C ÷ +90°C 

Operating Temperature 

+5°C ÷ +60°C 

Noise Level 

< 70 db (A) 

Compatible Barrel Sizes 

20/25Kg – 50Kg – 180/200 Kg 

Weight 

Models for 20/25Kg barrel 

10,7Kg 

MOdels for 50Kg Barrels  

11,2Kg 

Models for  180/200Kg 

l    

12Kg 

Summary of Contents for 0234560

Page 1: ...NS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT 14 PRECAUTIONS FOR USE 15 OPERATIONAL HAZARDS Manual compiled in a...

Page 2: ...ations Manufactured in high quality carbon steel the pump design features allow it to work with viscous lubricants without any additional complicated priming procedures The pump when combined with a s...

Page 3: ...duct for your application 4 TECHNICAL FEATURES GENERAL CHARACTERISTICS Pumping System Hydraulically activated Piston mechanism Lubricant Outlet Port 3 8 BSP UNI ISO 228 1 Return Line Port 1 4 BSP UNI...

Page 4: ...tant to inspect the pump to ensure that there has been no damage during transportation The packaging material used does not require any special disposal procedures You should refer to you regional req...

Page 5: ...l Inverter the electrically controlled valve switches the flow of oil from P A to P B and vice versa The user must not use a operating frequency less than 0 5 sec per change over Always ensure the int...

Page 6: ...substances and should be disposed of following local regulations including any recycling information indicated on the components themselves Upon demolition of the machine you must destroy the identifi...

Page 7: ...1141607 FOLLOWER PLATE 25KG D 320 1141602 FOLLOWER PLATE 50KG D375 1141604 FOLLOWER PLATE 200KG D580 3005141 LOCK RING 0234570 HYD INVERT AUTOMATIC CETOP 3 0234571 ELE INVERT 24VDC CETOP 3 0234572 EL...

Page 8: ...8 12 DIMENSIONS Dimensions in mm in...

Page 9: ...p LUBRICANTS The following is a comparison table between NLGI National Lubricating Grease Institute and ASTM American Society for Testing and Materials for greases showing the permissible values for t...

Page 10: ...g appropriate personal protective clothing and glasses Electrocution This can occur if the user does not securely connected the wires inside the terminal box Electrical connections must therefore be c...

Reviews: