15
5" LOCKING BAND
SCREWS
5" FLEXIBLE FLUE PIPE
8"RIGID AIR INLET PIPE
4" FOR BASEMENT OR DISTANT
INSTALLATION
4)
DISTANT INSTALLATION
It is possible to use up to 25 feet of pipe and a wall vent terminal or roof vent terminal ( no
E5700 ) However, the following restrictions must be applied. (see figure, next page)
- Maximum vertical lenght is 10 feet with the wall vent terminal.
- Maximum horizontal lenght is 10 feet
- Number of 45
°
or 90
°
elbows is three
•
For installation proceed in the same manner as the basement installation.
•
The venting distant kit ( No E-5705 ) contain:
- (15 feet) of 4" diameter, 2 plys flexible pipe
- (1)
4" diameter union
- (2)
locking bands
- (15 feet)
high temperature insulation
- (6)
spring spacers
- (24 feet)
of aluminium tape
- (30)
metal screws
- (1)
radiation shield
•
The following pieces must be supplied by the installer.
- Galvanized or black pipe minimum 24 gauges
- Appropriate roof flashing
- Roof braces ( if required )
•
The clearance between the pipe and the combustible wall must be 2" from the pipe additional
radiation shield can be ordered. Part number is E-5710.