13
•
Add a spring spacer. Spring spacer must be located opposite to the joints of the outside pipe
to prevent puncturing of the inside pipe when screwing two sections of the outside pipe
together.
•
Add sections of 8" diameter pipe and cut it to be flush with the outside face of exterior wall,
and install them to the 45
°
elbow, throught the radiation shield.
•
Seal the 8" diameter pipes and elbows joints with silicone.
•
The installation inside the house is now completed. The next step is to install the vent
termination cap following the instructions in the next section.
3) BASEMENT INSTALLATION:
- Make a 10-1\2" x10-1\2" opening in the wall to the desired position in the exterior wall.
- Cut the radiation shield to lenght, if necessary, and install as shown. Secure with four
(4) #10-1" wood screws.
- Install the vent pipes starting from the stove working your way out.
NOTE: All joints must be sealed with RTV silicone, 315
°
C (600
°
F) temperature resistance.
•
Fix the reducer 5” to 4” with screws and seal with silicone.
•
Fix the 4" flexible pipe to the reducer with locking band and seal with silicone. Cut to leave
a 2-1/2" projection over the exterior wall.
•
Slip on the 90
°
elbow facing upward.
•
Add a spring spacer. Spring spacers must be located opposite to the joints of the outside
pipes to prevent puncturing of the inside pipe when screwing two sections of the outside pipe
together.
•
Add 8" diameter pipe sections, including the spring spacers, to attain the desired height.
Secure with screws.
•
Slip on the 90
°
elbow and horizontally the last section of 8" pipe. The pipe has to be cut to
be flush with outside face of exterior wall, them install it through the radiation shield.
•
Seal the 8"diameter pipes and elbows joints with silicone.
•
The installation inside the house is now completed. The next step is to install the vent
termination cap following the instructions in the next section.