HeatMax II Furnace Installation and Operation Manual
50
Exhaust blowers that are in a fuel storage room should be installed so as not to create
negative pressure in the room where the solid fuel appliance is located.
A fresh air supply may be necessary to prevent solid fuel units from rejecting products of
combustion into the house. The indications used to determine if an additional fresh air
supply is necessary are not appropriate for all the situations. When in doubt, it is
recommended to install a fresh air supply.
A fresh air supply may be needed if:
-
Solid fuel units present anomalies, such as irregular draft, smoke return, bad
combustion, and/or reversed draft (whether there is combustion or not);
-
Existing solid fuel units such as a stove or fireplace release odours, heat badly, cause
smoke returns, or reversed draft (whether there is combustion or not );
-
The opening of a window, even slightly, in calm weather (windless), eliminates every
problem mentioned above ;
-
The house is equipped with a tight vapour barrier and adjusted windows, and/or is
equipped with an interior air mechanical evacuation device ;
-
There is excessive condensation on the windows in winter; and
-
The house is equipped with a ventilation system.
If, according to these symptoms or other similar ones, there is insufficient combustion air, it
is necessary to ensure an additional combustion air supply (see Section 6: Combustion
Air).
8.5 Manual or thermostat control
From factory, the opening and closing of the air inlet damper is manually activated by the
means of a switch located at the rear of the furnace. The switch has two positions; opened
and closed.
Position of the air control rod when the switch in the “closed” position.
Summary of Contents for HEATMAX II DF01001
Page 30: ...HeatMax II Furnace Installation and Operation Manual 30 ...
Page 64: ...HeatMax II Furnace Installation and Operation Manual 64 11 Exploded diagram and parts list ...
Page 65: ...HeatMax II Furnace Installation and Operation Manual 65 ...
Page 66: ...HeatMax II Furnace Installation and Operation Manual 66 ...
Page 67: ...HeatMax II Furnace Installation and Operation Manual 67 ...
Page 68: ...HeatMax II Furnace Installation and Operation Manual 68 ...
Page 74: ...HeatMax II Furnace Installation and Operation Manual 74 12 2 1 Technical data HeatMax II ...
Page 75: ...HeatMax II Furnace Installation and Operation Manual 75 ...