9.3.7 Hopper Lid Open
The hopper lid remained open for more than 3 minutes. As a security measure, the
auger stops turning and feeding pellets as soon as the hopper lid opens. It will resume
normal operation as soon as the hopper lid is closed. If the hopper lid stays open for
more than 3 minutes, the stove will stop.
The hopper lid safety switch is faulty or disconnected. Make sure that the switch
wiring is properly connected. If it is, the hopper switch may be faulty. Follow steps in
the troubleshooting page (see Section 9.2: Testing Components) and verify the
proper function of the safety switch. Replace if necessary.
9.3.8 Power Loss
Without auxiliary battery system
Power was interrupted while the stove was functioning. After the cool down cycle,
the stove will restart using the last settings. Press “RESET” to go back to the Main
Status Page.
With the optional battery backup system
Power was interrupted while the stove was functioning. The stove will
automatically switch to the auxiliary battery power and will continue to run. When the
battery voltage will be too low the stove will automatically shut down. Press “RESET” to
go back to the Main Status Page. You will be able to restart the stove when power is
back.
Summary of Contents for DP00065
Page 82: ...Edison Installation and Operation Manual 82 15 Replacement Parts ...
Page 83: ...Edison Installation and Operation Manual 83 ...
Page 84: ...Edison Installation and Operation Manual 84 ...
Page 85: ...Edison Installation and Operation Manual 85 ...
Page 86: ...Edison Installation and Operation Manual 86 ...
Page 87: ...Edison Installation and Operation Manual 87 ...
Page 88: ...Edison Installation and Operation Manual 88 ...